What size AC for Uvalde, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Uvalde needs

4 tons central AC or heat pump, about 47,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Hondo Municipal Airport (37.7 mi away). Aug is the hottest month, averaging a high of 97.2°F and a low of 72.3°F, with about 127 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 4,943 kWh a year at SEER2 14.3, or roughly $792 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Uvalde

Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of Uvalde's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Uvalde

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft25,2002 tons2 tons
1,500 sq ft36,5003 tons2.5 tons
2,500 sq ft59,0005 tons5 tons
3,000 sq ft70,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.

Month by month in Uvalde

MonthAvg highCooling degree daysAC kWh
Jan65.3°F711
Feb69.7°F2538
Mar75.8°F78122
Apr82.7°F177278
May88.3°F373586
Jun94.4°F534839
Jul96.7°F609957
Aug97.2°F612962
Sep91.4°F437687
Oct83.8°F229359
Nov73.3°F5687
Dec65.6°F1117

Aug alone uses 19% of the year's cooling energy. The unit runs the equivalent of 1,481 hours a year at full output.

Uvalde against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Eagle Pass, TX55 mi107°F4 tons
Del Rio, TX67 mi109°F4 tons
Kerrville, TX69 mi100°F3.5 tons
Helotes, TX71 mi104°F4 tons
Leon Valley, TX73 mi105°F4 tons
Boerne, TX74 mi101°F3.5 tons

Of 252 Texas cities here, Uvalde has the 60th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Uvalde's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Hondo Municipal Airport, 37.7 miles from the center of Uvalde at 922 ft above sea level. That is a long way for a weather station, so treat the design day as approximate: a city on the coast side or the high side of the station can run several degrees different.

No other city in this set uses Hondo Municipal Airport, so this sizing is Uvalde's alone.

The sun over Uvalde in late July

At 29.22°N, the noon sun on 21 July stands 81.2° above the horizon over Uvalde and the day runs 13 h 36 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

15,589 people live in Uvalde, the 191st largest of the 252 Texas cities sized on this site. Coordinates used: 29.2152, -99.7772.

Uvalde AC sizing questions

What size AC does a 2,000 sq ft house in Uvalde, TX need?

About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in Uvalde's climate.

Is 20 BTU per square foot right for Uvalde?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Hondo Municipal Airport. For a single room here, plan on 23.9 BTU/hr per square foot.

What does central AC cost to run in Uvalde?

About $792 a year: 4,943 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.