What size AC for Syracuse, NY? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Syracuse needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Syracuse Hancock International Airport (5.2 mi away). Jul is the hottest month, averaging a high of 81.7°F and a low of 62°F, with about 10 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 808 kWh a year at SEER2 14.3, or roughly $236 at New York's average residential rate of 29.26¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Syracuse

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Syracuse's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Syracuse

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Syracuse

MonthAvg highCooling degree daysAC kWh
Jan31.7°F00
Feb33.6°F00
Mar42.4°F00
Apr56.4°F45
May69.2°F3444
Jun77.3°F115150
Jul81.7°F218285
Aug80.3°F180235
Sep73.1°F6382
Oct60.1°F57
Nov48.3°F00
Dec37.1°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 464 hours a year at full output.

Syracuse against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Auburn, NY23 mi85°F2 tons
Fulton, NY24 mi84°F2 tons
Oneida, NY24 mi85°F2 tons
Cortland, NY30 mi83°F2 tons
Oswego, NY34 mi84°F2 tons
Rome, NY35 mi85°F2 tons

Of 90 New York cities here, Syracuse has the 59th highest cooling load. The range runs from Gloversville at 20,200 BTU/hr to Spring Valley at 33,400.

Where Syracuse's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Syracuse Hancock International Airport, 5.2 miles from the center of Syracuse at 410 ft above sea level. That is close enough that the station's summers are Syracuse's summers.

No other city in this set uses Syracuse Hancock International Airport, so this sizing is Syracuse's alone.

The sun over Syracuse in late July

At 43.04°N, the noon sun on 21 July stands 67.4° above the horizon over Syracuse and the day runs 14 h 43 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

146,097 people live in Syracuse, the 5th largest of the 90 New York cities sized on this site. Coordinates used: 43.0410, -76.1436.

Syracuse AC sizing questions

What size AC does a 2,000 sq ft house in Syracuse, NY need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Syracuse's climate.

Is 20 BTU per square foot right for Syracuse?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Syracuse Hancock International Airport. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Syracuse?

About $236 a year: 808 kWh at SEER2 14.3 and 29.26¢ per kWh, over 4 cooling months.