ACSizeCheck

What size AC for Sylacauga, AL? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Sylacauga needs

3.5 tons central AC or heat pump, about 36,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 651 square feet in this climate. For a single room, size by the room: 18.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Sylacauga 4 Ne (3.8 mi away). Jul is the hottest month, averaging a high of 90.3°F and a low of 68.5°F, with about 61 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.

What it costs to run

About 2,586 kWh a year at SEER2 14.3, or roughly $427 at Alabama's average residential rate of 16.51¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Sylacauga

Of the 36,900 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (41%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 6,700 is moisture the coil has to wring out of Sylacauga's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.

Other house sizes in Sylacauga

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,7001.5 tons2 tons
1,500 sq ft28,3002.5 tons2.5 tons
2,500 sq ft45,5004 tons5 tons
3,000 sq ft54,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,000 BTU/hr.

Month by month in Sylacauga

MonthAvg highCooling degree daysAC kWh
Jan54.5°F11
Feb58.7°F23
Mar66.7°F1116
Apr74.6°F4465
May81.3°F165244
Jun87.3°F337497
Jul90.3°F446658
Aug89.4°F415612
Sep85°F258380
Oct75.6°F6596
Nov65°F812
Dec56.8°F23

Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,002 hours a year at full output.

Sylacauga against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Talladega, AL20 mi96°F3.5 tons
Chelsea, AL22 mi97°F3.5 tons
Pell City, AL26 mi96°F3.5 tons
Alexander City, AL27 mi97°F3.5 tons
Calera, AL28 mi97°F3.5 tons
Pelham, AL29 mi97°F3.5 tons

Of 66 Alabama cities here, Sylacauga has the 51st highest cooling load. The range runs from Boaz at 30,600 BTU/hr to Montgomery at 44,000.

Where Sylacauga's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Sylacauga 4 Ne, 3.8 miles from the center of Sylacauga at 490 ft above sea level. That is close enough that the station's summers are Sylacauga's summers.

No other city in this set uses Sylacauga 4 Ne, so this sizing is Sylacauga's alone.

The sun over Sylacauga in late July

At 33.19°N, the noon sun on 21 July stands 77.2° above the horizon over Sylacauga and the day runs 13 h 53 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,123 people live in Sylacauga, the 59th largest of the 66 Alabama cities sized on this site. Coordinates used: 33.1887, -86.2748.

Sylacauga AC sizing questions

What size AC does a 2,000 sq ft house in Sylacauga, AL need?

About 3.5 tons, for a cooling load of 36,900 BTU/hr on a 96°F design day. That is one ton per 651 square feet in Sylacauga's climate.

Is 20 BTU per square foot right for Sylacauga?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Sylacauga 4 Ne. For a single room here, plan on 18.4 BTU/hr per square foot.

What does central AC cost to run in Sylacauga?

About $427 a year: 2,586 kWh at SEER2 14.3 and 16.51¢ per kWh, over 6 cooling months.