ACSizeCheck

What size AC for St. Louis, MO? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in St. Louis needs

3 tons central AC or heat pump, about 36,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Cahokia St. Louis Dwtn Airport (7.2 mi away). Jul is the hottest month, averaging a high of 89°F and a low of 68.8°F, with about 46 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.

What it costs to run

About 2,176 kWh a year at SEER2 14.3, or roughly $311 at Missouri's average residential rate of 14.28¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in St. Louis

Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of St. Louis's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.

Other house sizes in St. Louis

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft19,3001.5 tons2 tons
1,500 sq ft27,7002.5 tons2.5 tons
2,500 sq ft44,4004 tons5 tons
3,000 sq ft52,7005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.

Month by month in St. Louis

MonthAvg highCooling degree daysAC kWh
Jan40.2°F00
Feb45.6°F00
Mar56.3°F57
Apr67.5°F2739
May76.7°F130192
Jun85.7°F311458
Jul89°F431635
Aug87.8°F372548
Sep80.7°F162239
Oct69.4°F3653
Nov55.3°F23
Dec44.3°F00

Jul alone uses 29% of the year's cooling energy. The unit runs the equivalent of 864 hours a year at full output.

St. Louis against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Clayton, MO5 mi95°F3 tons
University City, MO5 mi95°F3 tons
Jennings, MO6 mi95°F3 tons
East St. Louis, IL6 mi95°F3 tons
Cahokia Heights, IL7 mi95°F3 tons
Webster Groves, MO7 mi95°F3 tons

Of 80 Missouri cities here, St. Louis has the 9th highest cooling load. The range runs from Hannibal at 30,600 BTU/hr to Sikeston at 37,800.

Where St. Louis's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Cahokia St. Louis Dwtn Airport, across the line in Illinois, 7.2 miles from the center of St. Louis at 405 ft above sea level. That is close enough that the station's summers are St. Louis's summers.

12 other cities use the same station and get the same climate inputs. The closest to St. Louis: East St. Louis (6 mi away, 3.8 mi from the station), Cahokia Heights (7 mi away, 0.7 mi from the station), Webster Groves (7 mi away, 11.2 mi from the station), Crestwood (9 mi away, 12.4 mi from the station), Granite City (9 mi away, 11.5 mi from the station). St. Louis is farther from the station than 2 of them.

The sun over St. Louis in late July

At 38.64°N, the noon sun on 21 July stands 71.8° above the horizon over St. Louis and the day runs 14 h 18 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

279,695 people live in St. Louis, the 2nd largest of the 80 Missouri cities sized on this site. Coordinates used: 38.6357, -90.2446.

St. Louis AC sizing questions

What size AC does a 2,000 sq ft house in St. Louis, MO need?

About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in St. Louis's climate.

Is 20 BTU per square foot right for St. Louis?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Cahokia St. Louis Dwtn Airport. For a single room here, plan on 18 BTU/hr per square foot.

What does central AC cost to run in St. Louis?

About $311 a year: 2,176 kWh at SEER2 14.3 and 14.28¢ per kWh, over 5 cooling months.