What size AC for Springville, UT? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Springville needs
3.5 tons central AC or heat pump, about 37,300 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.1 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 643 square feet in this climate. For a single room, size by the room: 18.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Provo Byu (5.9 mi away). Jul is the hottest month, averaging a high of 95.2°F and a low of 62.3°F, with about 74 days a year at 90°F or more. That gives a design temperature of 102°F against 75°F inside.
What it costs to run
About 1,572 kWh a year at SEER2 14.3, or roughly $207 at Utah's average residential rate of 13.19¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Springville
Of the 37,300 BTU/hr, 19,440 comes through walls, roof and windows on a 102°F afternoon (52%), 13,000 is sun on the house (35%), 2,120 is four people and their appliances, and 2,800 is moisture the coil has to wring out of Springville's summer air (8%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 34,560 BTU/hr before the moisture allowance.
Other house sizes in Springville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,800 | 1.5 tons | 2 tons |
| 1,500 sq ft | 28,600 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 46,100 | 4 tons | 5 tons |
| 3,000 sq ft | 54,800 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,800 BTU/hr; a 350 sq ft living room needs about 6,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,200 BTU/hr.
Month by month in Springville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 41.2°F | 0 | 0 |
| Feb | 47.6°F | 0 | 0 |
| Mar | 58.4°F | 0 | 0 |
| Apr | 65.6°F | 4 | 5 |
| May | 75.7°F | 51 | 67 |
| Jun | 87.2°F | 213 | 278 |
| Jul | 95.2°F | 427 | 557 |
| Aug | 92.9°F | 372 | 485 |
| Sep | 83.1°F | 130 | 170 |
| Oct | 68.5°F | 8 | 10 |
| Nov | 53.2°F | 0 | 0 |
| Dec | 41.4°F | 0 | 0 |
Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 602 hours a year at full output.
Springville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Spanish Fork, UT | 4 mi | 99°F | 3 tons |
| Mapleton, UT | 4 mi | 99°F | 3 tons |
| Provo, UT | 6 mi | 102°F | 3.5 tons |
| Salem, UT | 8 mi | 99°F | 3 tons |
| Orem, UT | 10 mi | 98°F | 3 tons |
| Payson, UT | 11 mi | 96°F | 3 tons |
Of 67 Utah cities here, Springville has the 29th highest cooling load. The range runs from Heber at 30,700 BTU/hr to St. George at 49,200.
Where Springville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Provo Byu, 5.9 miles from the center of Springville at 4,570 ft above sea level. That is close enough that the station's summers are Springville's summers.
1 other city uses the same station and get the same climate inputs. The closest to Springville: Provo (6 mi away, 0.3 mi from the station). Springville is farther from the station than 1 of them.
The sun over Springville in late July
At 40.16°N, the noon sun on 21 July stands 70.2° above the horizon over Springville and the day runs 14 h 26 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
36,027 people live in Springville, the 31st largest of the 67 Utah cities sized on this site. Coordinates used: 40.1643, -111.6195.
Springville AC sizing questions
What size AC does a 2,000 sq ft house in Springville, UT need?
About 3.5 tons, for a cooling load of 37,300 BTU/hr on a 102°F design day. That is one ton per 643 square feet in Springville's climate.
Is 20 BTU per square foot right for Springville?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Provo Byu. For a single room here, plan on 18.7 BTU/hr per square foot.
What does central AC cost to run in Springville?
About $207 a year: 1,572 kWh at SEER2 14.3 and 13.19¢ per kWh, over 5 cooling months.