ACSizeCheck

What size AC for South Milwaukee, WI? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in South Milwaukee needs

2.5 tons central AC or heat pump, about 26,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 906 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Milwaukee Mitchell Airport (3.6 mi away). Jul is the hottest month, averaging a high of 81.9°F and a low of 64.7°F, with about 9 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 1,084 kWh a year at SEER2 14.3, or roughly $206 at Wisconsin's average residential rate of 19.05¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in South Milwaukee

Of the 26,500 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (30%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 3,500 is moisture the coil has to wring out of South Milwaukee's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in South Milwaukee

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,5001.5 tons2 tons
1,500 sq ft20,5002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in South Milwaukee

MonthAvg highCooling degree daysAC kWh
Jan30.9°F00
Feb34.2°F00
Mar44.2°F11
Apr54.7°F45
May66.5°F3448
Jun76.8°F142197
Jul81.9°F263366
Aug80.3°F232323
Sep73.5°F93129
Oct61.3°F1115
Nov47.8°F01
Dec36.1°F00

Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 585 hours a year at full output.

South Milwaukee against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Cudahy, WI2 mi86°F2.5 tons
Oak Creek, WI3 mi86°F2.5 tons
Greendale, WI7 mi86°F2.5 tons
Franklin, WI8 mi86°F2.5 tons
Greenfield, WI8 mi86°F2.5 tons
Caledonia, WI8 mi86°F2 tons

Of 98 Wisconsin cities here, South Milwaukee has the 17th highest cooling load. The range runs from Two Rivers at 20,200 BTU/hr to La Crosse at 29,800.

Where South Milwaukee's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Milwaukee Mitchell Airport, 3.6 miles from the center of South Milwaukee at 667 ft above sea level. That is close enough that the station's summers are South Milwaukee's summers.

17 other cities use the same station and get the same climate inputs. The closest to South Milwaukee: Cudahy (2 mi away, 2.1 mi from the station), Oak Creek (3 mi away, 5.3 mi from the station), Greendale (7 mi away, 5 mi from the station), Franklin (8 mi away, 7.3 mi from the station), Greenfield (8 mi away, 5.1 mi from the station). South Milwaukee is farther from the station than 1 of them.

The sun over South Milwaukee in late July

At 42.91°N, the noon sun on 21 July stands 67.5° above the horizon over South Milwaukee and the day runs 14 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

20,233 people live in South Milwaukee, the 41st largest of the 98 Wisconsin cities sized on this site. Coordinates used: 42.9126, -87.8623.

South Milwaukee AC sizing questions

What size AC does a 2,000 sq ft house in South Milwaukee, WI need?

About 2.5 tons, for a cooling load of 26,500 BTU/hr on a 86°F design day. That is one ton per 906 square feet in South Milwaukee's climate.

Is 20 BTU per square foot right for South Milwaukee?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Milwaukee Mitchell Airport. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in South Milwaukee?

About $206 a year: 1,084 kWh at SEER2 14.3 and 19.05¢ per kWh, over 4 cooling months.