ACSizeCheck

What size AC for Sheboygan, WI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Sheboygan needs

2 tons central AC or heat pump, about 23,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 80% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,029 square feet in this climate. For a single room, size by the room: 11.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Sheboygan County Mem Airport (6.4 mi away). Jul is the hottest month, averaging a high of 80.2°F and a low of 58.3°F, with about 6 days a year at 90°F or more. That gives a design temperature of 84°F against 75°F inside.

What it costs to run

About 531 kWh a year at SEER2 14.3, or roughly $101 at Wisconsin's average residential rate of 19.05¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Sheboygan

Of the 23,300 BTU/hr, 6,480 comes through walls, roof and windows on a 84°F afternoon (28%), 13,000 is sun on the house (56%), 2,120 is four people and their appliances, and 1,700 is moisture the coil has to wring out of Sheboygan's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 21,600 BTU/hr before the moisture allowance.

Other house sizes in Sheboygan

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft12,8001.5 tons2 tons
1,500 sq ft18,1001.5 tons2.5 tons
2,500 sq ft28,6002.5 tons5 tons
3,000 sq ft33,8003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,100 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,000 BTU/hr.

Month by month in Sheboygan

MonthAvg highCooling degree daysAC kWh
Jan26.9°F00
Feb30°F00
Mar40.5°F00
Apr52.5°F00
May64.8°F1317
Jun75.4°F78102
Jul80.2°F157205
Aug78.2°F118154
Sep71.3°F3749
Oct58.1°F34
Nov44.3°F00
Dec32.5°F00

Jul alone uses 39% of the year's cooling energy. The unit runs the equivalent of 326 hours a year at full output.

Sheboygan against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Manitowoc, WI25 mi81°F2 tons
Port Washington, WI26 mi83°F2 tons
Two Rivers, WI30 mi80°F2 tons
Grafton, WI31 mi85°F2 tons
West Bend, WI32 mi86°F2 tons
Cedarburg, WI33 mi85°F2 tons

Of 98 Wisconsin cities here, Sheboygan has the 86th highest cooling load. The range runs from Two Rivers at 20,200 BTU/hr to La Crosse at 29,800.

Where Sheboygan's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Sheboygan County Mem Airport, 6.4 miles from the center of Sheboygan at 751 ft above sea level. That is close enough that the station's summers are Sheboygan's summers.

No other city in this set uses Sheboygan County Mem Airport, so this sizing is Sheboygan's alone.

The sun over Sheboygan in late July

At 43.74°N, the noon sun on 21 July stands 66.7° above the horizon over Sheboygan and the day runs 14 h 47 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

49,624 people live in Sheboygan, the 13th largest of the 98 Wisconsin cities sized on this site. Coordinates used: 43.7387, -87.7315.

Sheboygan AC sizing questions

What size AC does a 2,000 sq ft house in Sheboygan, WI need?

About 2 tons, for a cooling load of 23,300 BTU/hr on a 84°F design day. That is one ton per 1,029 square feet in Sheboygan's climate.

Is 20 BTU per square foot right for Sheboygan?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Sheboygan County Mem Airport. For a single room here, plan on 11.7 BTU/hr per square foot.

What does central AC cost to run in Sheboygan?

About $101 a year: 531 kWh at SEER2 14.3 and 19.05¢ per kWh, over 3 cooling months.