What size AC for Rexburg, ID? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Rexburg needs
2.5 tons central AC or heat pump, about 26,200 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 60% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 916 square feet in this climate. For a single room, size by the room: 13.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Rexburg Madison County Airport (1 mi away). Jul is the hottest month, averaging a high of 84.8°F and a low of 51.6°F, with about 18 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.
What it costs to run
About 324 kWh a year at SEER2 14.3, or roughly $42 at Idaho's average residential rate of 13.02¢ per kWh. Cooling runs 2 months of the year here.
What drives the load in Rexburg
Of the 26,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (38%), 13,000 is sun on the house (50%), 2,120 is four people and their appliances, and 1,000 is moisture the coil has to wring out of Rexburg's summer air (4%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.
Other house sizes in Rexburg
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,200 | 1.5 tons | 2 tons |
| 1,500 sq ft | 20,200 | 2 tons | 2.5 tons |
| 2,500 sq ft | 32,200 | 3 tons | 5 tons |
| 3,000 sq ft | 38,200 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.
Month by month in Rexburg
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 27.8°F | 0 | 0 |
| Feb | 32.2°F | 0 | 0 |
| Mar | 45.1°F | 0 | 0 |
| Apr | 55.5°F | 0 | 0 |
| May | 65.9°F | 3 | 4 |
| Jun | 74.2°F | 23 | 29 |
| Jul | 84.8°F | 122 | 153 |
| Aug | 84.2°F | 98 | 123 |
| Sep | 73.1°F | 11 | 14 |
| Oct | 57.3°F | 0 | 0 |
| Nov | 41.3°F | 0 | 0 |
| Dec | 29.3°F | 0 | 0 |
Jul alone uses 47% of the year's cooling energy. The unit runs the equivalent of 177 hours a year at full output.
Rexburg against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Ammon, ID | 25 mi | 91°F | 2.5 tons |
| Idaho Falls, ID | 26 mi | 91°F | 2.5 tons |
| Blackfoot, ID | 52 mi | 92°F | 2.5 tons |
| Jackson, WY | 56 mi | 83°F | 2 tons |
| Chubbuck, ID | 70 mi | 95°F | 2.5 tons |
| Pocatello, ID | 74 mi | 95°F | 2.5 tons |
Of 26 Idaho cities here, Rexburg has the 22nd highest cooling load. The range runs from Sandpoint at 24,000 BTU/hr to Mountain Home at 36,500.
Where Rexburg's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Rexburg Madison County Airport, 1 miles from the center of Rexburg at 4,858 ft above sea level. That is close enough that the station's summers are Rexburg's summers.
No other city in this set uses Rexburg Madison County Airport, so this sizing is Rexburg's alone.
The sun over Rexburg in late July
At 43.82°N, the noon sun on 21 July stands 66.6° above the horizon over Rexburg and the day runs 14 h 47 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
40,695 people live in Rexburg, the 10th largest of the 26 Idaho cities sized on this site. Coordinates used: 43.8229, -111.7910.
Rexburg AC sizing questions
What size AC does a 2,000 sq ft house in Rexburg, ID need?
About 2.5 tons, for a cooling load of 26,200 BTU/hr on a 89°F design day. That is one ton per 916 square feet in Rexburg's climate.
Is 20 BTU per square foot right for Rexburg?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Rexburg Madison County Airport. For a single room here, plan on 13.1 BTU/hr per square foot.
What does central AC cost to run in Rexburg?
About $42 a year: 324 kWh at SEER2 14.3 and 13.02¢ per kWh, over 2 cooling months.