ACSizeCheck

What size AC for Plainfield, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Plainfield needs

2.5 tons central AC or heat pump, about 27,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 882 square feet in this climate. For a single room, size by the room: 13.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago Aurora Municipal Airport (16.8 mi away). Jul is the hottest month, averaging a high of 84.4°F and a low of 61.8°F, with about 16 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,019 kWh a year at SEER2 14.3, or roughly $196 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Plainfield

Of the 27,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (37%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Plainfield's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Plainfield

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,8001.5 tons2 tons
1,500 sq ft21,0002 tons2.5 tons
2,500 sq ft33,4003 tons5 tons
3,000 sq ft39,7003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.

Month by month in Plainfield

MonthAvg highCooling degree daysAC kWh
Jan30.5°F00
Feb34.9°F00
Mar47.5°F12
Apr60.4°F56
May71.9°F5673
Jun81.4°F177232
Jul84.4°F257335
Aug82.2°F193252
Sep76.2°F80105
Oct63.3°F1114
Nov48.1°F00
Dec35.8°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 536 hours a year at full output.

Plainfield against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Romeoville, IL7 mi89°F2.5 tons
Crest Hill, IL7 mi89°F2.5 tons
Shorewood, IL7 mi88°F2.5 tons
Oswego, IL7 mi89°F2.5 tons
Bolingbrook, IL8 mi88°F2.5 tons
Joliet, IL8 mi88°F2.5 tons

Of 225 Illinois cities here, Plainfield has the 166th highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Plainfield's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago Aurora Municipal Airport, 16.8 miles from the center of Plainfield at 701 ft above sea level. That is close enough that the station's summers are Plainfield's summers.

5 other cities use the same station and get the same climate inputs. The closest to Plainfield: Oswego (7 mi away, 9.5 mi from the station), Montgomery (10 mi away, 7.2 mi from the station), Yorkville (11 mi away, 8.1 mi from the station), North Aurora (14 mi away, 7.6 mi from the station), Plano (17 mi away, 6.9 mi from the station). Plainfield is farther from the station than 5 of them.

The sun over Plainfield in late July

At 41.62°N, the noon sun on 21 July stands 68.8° above the horizon over Plainfield and the day runs 14 h 34 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

48,881 people live in Plainfield, the 31st largest of the 225 Illinois cities sized on this site. Coordinates used: 41.6197, -88.2269.

Plainfield AC sizing questions

What size AC does a 2,000 sq ft house in Plainfield, IL need?

About 2.5 tons, for a cooling load of 27,200 BTU/hr on a 89°F design day. That is one ton per 882 square feet in Plainfield's climate.

Is 20 BTU per square foot right for Plainfield?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Aurora Municipal Airport. For a single room here, plan on 13.6 BTU/hr per square foot.

What does central AC cost to run in Plainfield?

About $196 a year: 1,019 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.