ACSizeCheck

What size AC for Pineville, LA? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Pineville needs

3.5 tons central AC or heat pump, about 41,300 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 581 square feet in this climate. For a single room, size by the room: 20.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Alexandria Esler Field (8.3 mi away). Aug is the hottest month, averaging a high of 93.6°F and a low of 70.1°F, with about 102 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 3,580 kWh a year at SEER2 14.3, or roughly $475 at Louisiana's average residential rate of 13.27¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Pineville

Of the 41,300 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (45%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,400 is moisture the coil has to wring out of Pineville's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Pineville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,9002 tons2 tons
1,500 sq ft31,6003 tons2.5 tons
2,500 sq ft51,0004 tons5 tons
3,000 sq ft60,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,100 BTU/hr; a 350 sq ft living room needs about 7,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,400 BTU/hr.

Month by month in Pineville

MonthAvg highCooling degree daysAC kWh
Jan59.9°F69
Feb64.2°F1319
Mar71.5°F4059
Apr78.1°F99146
May85.1°F264389
Jun90.8°F435641
Jul93.1°F529779
Aug93.6°F522770
Sep89.2°F360530
Oct80°F127186
Nov69.4°F2333
Dec61.9°F1117

Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,240 hours a year at full output.

Pineville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Alexandria, LA5 mi101°F3.5 tons
Natchitoches, LA49 mi103°F4 tons
Opelousas, LA60 mi99°F4 tons
Natchez, MS62 mi96°F3.5 tons
Carencro, LA74 mi99°F4 tons
Crowley, LA78 mi98°F3.5 tons

Of 35 Louisiana cities here, Pineville has the 24th highest cooling load. The range runs from Covington at 37,800 BTU/hr to Natchitoches at 45,900.

Where Pineville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Alexandria Esler Field, 8.3 miles from the center of Pineville at 88 ft above sea level. That is close enough that the station's summers are Pineville's summers.

No other city in this set uses Alexandria Esler Field, so this sizing is Pineville's alone.

The sun over Pineville in late July

At 31.34°N, the noon sun on 21 July stands 79.1° above the horizon over Pineville and the day runs 13 h 45 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

13,966 people live in Pineville, the 24th largest of the 35 Louisiana cities sized on this site. Coordinates used: 31.3429, -92.4089.

Pineville AC sizing questions

What size AC does a 2,000 sq ft house in Pineville, LA need?

About 3.5 tons, for a cooling load of 41,300 BTU/hr on a 101°F design day. That is one ton per 581 square feet in Pineville's climate.

Is 20 BTU per square foot right for Pineville?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Alexandria Esler Field. For a single room here, plan on 20.6 BTU/hr per square foot.

What does central AC cost to run in Pineville?

About $475 a year: 3,580 kWh at SEER2 14.3 and 13.27¢ per kWh, over 7 cooling months.