What size AC for Pineville, LA? 3.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Pineville needs
3.5 tons central AC or heat pump, about 41,300 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 581 square feet in this climate. For a single room, size by the room: 20.6 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Alexandria Esler Field (8.3 mi away). Aug is the hottest month, averaging a high of 93.6°F and a low of 70.1°F, with about 102 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.
What it costs to run
About 3,580 kWh a year at SEER2 14.3, or roughly $475 at Louisiana's average residential rate of 13.27¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Pineville
Of the 41,300 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (45%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 7,400 is moisture the coil has to wring out of Pineville's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.
Other house sizes in Pineville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 21,900 | 2 tons | 2 tons |
| 1,500 sq ft | 31,600 | 3 tons | 2.5 tons |
| 2,500 sq ft | 51,000 | 4 tons | 5 tons |
| 3,000 sq ft | 60,600 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,100 BTU/hr; a 350 sq ft living room needs about 7,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,400 BTU/hr.
Month by month in Pineville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 59.9°F | 6 | 9 |
| Feb | 64.2°F | 13 | 19 |
| Mar | 71.5°F | 40 | 59 |
| Apr | 78.1°F | 99 | 146 |
| May | 85.1°F | 264 | 389 |
| Jun | 90.8°F | 435 | 641 |
| Jul | 93.1°F | 529 | 779 |
| Aug | 93.6°F | 522 | 770 |
| Sep | 89.2°F | 360 | 530 |
| Oct | 80°F | 127 | 186 |
| Nov | 69.4°F | 23 | 33 |
| Dec | 61.9°F | 11 | 17 |
Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,240 hours a year at full output.
Pineville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Alexandria, LA | 5 mi | 101°F | 3.5 tons |
| Natchitoches, LA | 49 mi | 103°F | 4 tons |
| Opelousas, LA | 60 mi | 99°F | 4 tons |
| Natchez, MS | 62 mi | 96°F | 3.5 tons |
| Carencro, LA | 74 mi | 99°F | 4 tons |
| Crowley, LA | 78 mi | 98°F | 3.5 tons |
Of 35 Louisiana cities here, Pineville has the 24th highest cooling load. The range runs from Covington at 37,800 BTU/hr to Natchitoches at 45,900.
Where Pineville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Alexandria Esler Field, 8.3 miles from the center of Pineville at 88 ft above sea level. That is close enough that the station's summers are Pineville's summers.
No other city in this set uses Alexandria Esler Field, so this sizing is Pineville's alone.
The sun over Pineville in late July
At 31.34°N, the noon sun on 21 July stands 79.1° above the horizon over Pineville and the day runs 13 h 45 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
13,966 people live in Pineville, the 24th largest of the 35 Louisiana cities sized on this site. Coordinates used: 31.3429, -92.4089.
Pineville AC sizing questions
What size AC does a 2,000 sq ft house in Pineville, LA need?
About 3.5 tons, for a cooling load of 41,300 BTU/hr on a 101°F design day. That is one ton per 581 square feet in Pineville's climate.
Is 20 BTU per square foot right for Pineville?
The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Alexandria Esler Field. For a single room here, plan on 20.6 BTU/hr per square foot.
What does central AC cost to run in Pineville?
About $475 a year: 3,580 kWh at SEER2 14.3 and 13.27¢ per kWh, over 7 cooling months.