ACSizeCheck

What size AC for Patchogue, NY? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Patchogue needs

2.5 tons central AC or heat pump, about 27,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 878 square feet in this climate. For a single room, size by the room: 13.7 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Islip-Li Macarthur Airport (4.8 mi away). Jul is the hottest month, averaging a high of 82.8°F and a low of 67.3°F, with about 8 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 1,230 kWh a year at SEER2 14.3, or roughly $360 at New York's average residential rate of 29.26¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Patchogue

Of the 27,300 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (32%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 3,600 is moisture the coil has to wring out of Patchogue's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Patchogue

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,9001.5 tons2 tons
1,500 sq ft21,1002 tons2.5 tons
2,500 sq ft33,5003 tons5 tons
3,000 sq ft39,8003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,100 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.

Month by month in Patchogue

MonthAvg highCooling degree daysAC kWh
Jan39.2°F00
Feb41°F00
Mar47.7°F00
Apr58.3°F33
May68.3°F2737
Jun77.2°F152211
Jul82.8°F312434
Aug81.4°F271377
Sep74.8°F108150
Oct64.1°F1318
Nov53.6°F00
Dec44.4°F00

Jul alone uses 35% of the year's cooling energy. The unit runs the equivalent of 644 hours a year at full output.

Patchogue against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lake Grove, NY8 mi87°F2.5 tons
Babylon, NY17 mi87°F2.5 tons
Lindenhurst, NY19 mi87°F2.5 tons
Massapequa Park, NY23 mi87°F2.5 tons
Westbury, NY30 mi87°F2.5 tons
Freeport, NY31 mi88°F2.5 tons

Of 90 New York cities here, Patchogue has the 39th highest cooling load. The range runs from Gloversville at 20,200 BTU/hr to Spring Valley at 33,400.

Where Patchogue's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Islip-Li Macarthur Airport, 4.8 miles from the center of Patchogue at 83 ft above sea level. That is close enough that the station's summers are Patchogue's summers.

1 other city uses the same station and get the same climate inputs. The closest to Patchogue: Lake Grove (8 mi away, 4.5 mi from the station). Patchogue is farther from the station than 1 of them.

The sun over Patchogue in late July

At 40.76°N, the noon sun on 21 July stands 69.6° above the horizon over Patchogue and the day runs 14 h 30 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

12,447 people live in Patchogue, the 67th largest of the 90 New York cities sized on this site. Coordinates used: 40.7637, -73.0198.

Patchogue AC sizing questions

What size AC does a 2,000 sq ft house in Patchogue, NY need?

About 2.5 tons, for a cooling load of 27,300 BTU/hr on a 87°F design day. That is one ton per 878 square feet in Patchogue's climate.

Is 20 BTU per square foot right for Patchogue?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Islip-Li Macarthur Airport. For a single room here, plan on 13.7 BTU/hr per square foot.

What does central AC cost to run in Patchogue?

About $360 a year: 1,230 kWh at SEER2 14.3 and 29.26¢ per kWh, over 4 cooling months.