ACSizeCheck

What size AC for Okmulgee, OK? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Okmulgee needs

3.5 tons central AC or heat pump, about 39,500 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.3 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 607 square feet in this climate. For a single room, size by the room: 19.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Okmulgee Wtr Wks (4 mi away). Jul is the hottest month, averaging a high of 92.9°F and a low of 70.2°F, with about 67 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 2,672 kWh a year at SEER2 14.3, or roughly $369 at Oklahoma's average residential rate of 13.81¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Okmulgee

Of the 39,500 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (44%), 13,000 is sun on the house (33%), 2,120 is four people and their appliances, and 7,100 is moisture the coil has to wring out of Okmulgee's summer air (18%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Okmulgee

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft21,1002 tons2 tons
1,500 sq ft30,3002.5 tons2.5 tons
2,500 sq ft48,8004 tons5 tons
3,000 sq ft58,0005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,000 BTU/hr; a 350 sq ft living room needs about 6,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,900 BTU/hr.

Month by month in Okmulgee

MonthAvg highCooling degree daysAC kWh
Jan49.6°F00
Feb54.8°F01
Mar63.5°F812
Apr72.3°F3957
May78.7°F141207
Jun87.3°F350516
Jul92.9°F513756
Aug92.2°F464683
Sep84.4°F237350
Oct74.5°F5581
Nov62.1°F68
Dec53.2°F00

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 967 hours a year at full output.

Okmulgee against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Bixby, OK23 mi101°F4 tons
Glenpool, OK23 mi101°F4 tons
Jenks, OK26 mi101°F4 tons
Sapulpa, OK28 mi101°F4 tons
Coweta, OK29 mi101°F4 tons
Broken Arrow, OK30 mi101°F4 tons

Of 45 Oklahoma cities here, Okmulgee has the 43rd highest cooling load. The range runs from Miami at 35,600 BTU/hr to Ardmore at 44,900.

Where Okmulgee's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Okmulgee Wtr Wks, 4 miles from the center of Okmulgee at 647 ft above sea level. That is close enough that the station's summers are Okmulgee's summers.

No other city in this set uses Okmulgee Wtr Wks, so this sizing is Okmulgee's alone.

The sun over Okmulgee in late July

At 35.63°N, the noon sun on 21 July stands 74.8° above the horizon over Okmulgee and the day runs 14 h 04 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

11,354 people live in Okmulgee, the 43rd largest of the 45 Oklahoma cities sized on this site. Coordinates used: 35.6252, -95.9540.

Okmulgee AC sizing questions

What size AC does a 2,000 sq ft house in Okmulgee, OK need?

About 3.5 tons, for a cooling load of 39,500 BTU/hr on a 99°F design day. That is one ton per 607 square feet in Okmulgee's climate.

Is 20 BTU per square foot right for Okmulgee?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Okmulgee Wtr Wks. For a single room here, plan on 19.8 BTU/hr per square foot.

What does central AC cost to run in Okmulgee?

About $369 a year: 2,672 kWh at SEER2 14.3 and 13.81¢ per kWh, over 6 cooling months.