ACSizeCheck

What size AC for Northlake, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Northlake needs

4 tons central AC or heat pump, about 47,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Fort Worth Alliance Airport (6.6 mi away). Jul is the hottest month, averaging a high of 96.9°F and a low of 76.4°F, with about 108 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 4,602 kWh a year at SEER2 14.3, or roughly $738 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Northlake

Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of Northlake's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Northlake

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft25,2002 tons2 tons
1,500 sq ft36,5003 tons2.5 tons
2,500 sq ft59,0005 tons5 tons
3,000 sq ft70,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.

Month by month in Northlake

MonthAvg highCooling degree daysAC kWh
Jan57.4°F35
Feb61.6°F1016
Mar69.2°F4165
Apr76.5°F110172
May84.1°F298469
Jun92.7°F532836
Jul96.9°F6711,054
Aug96.9°F6651,044
Sep89.2°F405637
Oct78.9°F156246
Nov67.4°F3149
Dec58.5°F69

Jul alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,379 hours a year at full output.

Northlake against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Roanoke, TX4 mi105°F4 tons
Trophy Club, TX7 mi105°F4 tons
Flower Mound, TX9 mi103°F4 tons
Keller, TX10 mi105°F4 tons
Southlake, TX10 mi103°F4 tons
Highland Village, TX11 mi103°F4 tons

Of 252 Texas cities here, Northlake has the 68th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Northlake's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Fort Worth Alliance Airport, 6.6 miles from the center of Northlake at 707 ft above sea level. That is close enough that the station's summers are Northlake's summers.

3 other cities use the same station and get the same climate inputs. The closest to Northlake: Roanoke (4 mi away, 5.5 mi from the station), Trophy Club (7 mi away, 8.5 mi from the station), Keller (10 mi away, 7 mi from the station). Northlake is farther from the station than 1 of them.

The sun over Northlake in late July

At 33.07°N, the noon sun on 21 July stands 77.3° above the horizon over Northlake and the day runs 13 h 52 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

10,746 people live in Northlake, the 237th largest of the 252 Texas cities sized on this site. Coordinates used: 33.0738, -97.2562.

Northlake AC sizing questions

What size AC does a 2,000 sq ft house in Northlake, TX need?

About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in Northlake's climate.

Is 20 BTU per square foot right for Northlake?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Fort Worth Alliance Airport. For a single room here, plan on 23.9 BTU/hr per square foot.

What does central AC cost to run in Northlake?

About $738 a year: 4,602 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.