What size AC for Northlake, TX? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Northlake needs
4 tons central AC or heat pump, about 47,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Fort Worth Alliance Airport (6.6 mi away). Jul is the hottest month, averaging a high of 96.9°F and a low of 76.4°F, with about 108 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.
What it costs to run
About 4,602 kWh a year at SEER2 14.3, or roughly $738 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Northlake
Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of Northlake's summer air (23%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.
Other house sizes in Northlake
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 25,200 | 2 tons | 2 tons |
| 1,500 sq ft | 36,500 | 3 tons | 2.5 tons |
| 2,500 sq ft | 59,000 | 5 tons | 5 tons |
| 3,000 sq ft | 70,200 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.
Month by month in Northlake
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 57.4°F | 3 | 5 |
| Feb | 61.6°F | 10 | 16 |
| Mar | 69.2°F | 41 | 65 |
| Apr | 76.5°F | 110 | 172 |
| May | 84.1°F | 298 | 469 |
| Jun | 92.7°F | 532 | 836 |
| Jul | 96.9°F | 671 | 1,054 |
| Aug | 96.9°F | 665 | 1,044 |
| Sep | 89.2°F | 405 | 637 |
| Oct | 78.9°F | 156 | 246 |
| Nov | 67.4°F | 31 | 49 |
| Dec | 58.5°F | 6 | 9 |
Jul alone uses 23% of the year's cooling energy. The unit runs the equivalent of 1,379 hours a year at full output.
Northlake against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Roanoke, TX | 4 mi | 105°F | 4 tons |
| Trophy Club, TX | 7 mi | 105°F | 4 tons |
| Flower Mound, TX | 9 mi | 103°F | 4 tons |
| Keller, TX | 10 mi | 105°F | 4 tons |
| Southlake, TX | 10 mi | 103°F | 4 tons |
| Highland Village, TX | 11 mi | 103°F | 4 tons |
Of 252 Texas cities here, Northlake has the 68th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.
Where Northlake's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Fort Worth Alliance Airport, 6.6 miles from the center of Northlake at 707 ft above sea level. That is close enough that the station's summers are Northlake's summers.
3 other cities use the same station and get the same climate inputs. The closest to Northlake: Roanoke (4 mi away, 5.5 mi from the station), Trophy Club (7 mi away, 8.5 mi from the station), Keller (10 mi away, 7 mi from the station). Northlake is farther from the station than 1 of them.
The sun over Northlake in late July
At 33.07°N, the noon sun on 21 July stands 77.3° above the horizon over Northlake and the day runs 13 h 52 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
10,746 people live in Northlake, the 237th largest of the 252 Texas cities sized on this site. Coordinates used: 33.0738, -97.2562.
Northlake AC sizing questions
What size AC does a 2,000 sq ft house in Northlake, TX need?
About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in Northlake's climate.
Is 20 BTU per square foot right for Northlake?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Fort Worth Alliance Airport. For a single room here, plan on 23.9 BTU/hr per square foot.
What does central AC cost to run in Northlake?
About $738 a year: 4,602 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.