What size AC for Northglenn, CO? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Northglenn needs
3 tons central AC or heat pump, about 32,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 29% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 735 square feet in this climate. For a single room, size by the room: 16.3 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Denver-Stapleton (11.9 mi away). Jul is the hottest month, averaging a high of 90.2°F and a low of 59.3°F, with about 42 days a year at 90°F or more. That gives a design temperature of 96°F against 75°F inside.
What it costs to run
About 1,061 kWh a year at SEER2 14.3, or roughly $178 at Colorado's average residential rate of 16.8¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in Northglenn
Of the 32,700 BTU/hr, 15,120 comes through walls, roof and windows on a 96°F afternoon (46%), 13,000 is sun on the house (40%), 2,120 is four people and their appliances, and 2,400 is moisture the coil has to wring out of Northglenn's summer air (7%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,240 BTU/hr before the moisture allowance.
Other house sizes in Northglenn
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 17,500 | 1.5 tons | 2 tons |
| 1,500 sq ft | 25,100 | 2 tons | 2.5 tons |
| 2,500 sq ft | 40,300 | 3.5 tons | 5 tons |
| 3,000 sq ft | 47,800 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,800 BTU/hr.
Month by month in Northglenn
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 46.5°F | 0 | 0 |
| Feb | 47.5°F | 0 | 0 |
| Mar | 56.4°F | 0 | 0 |
| Apr | 62.5°F | 1 | 1 |
| May | 71.7°F | 26 | 33 |
| Jun | 84.1°F | 151 | 197 |
| Jul | 90.2°F | 306 | 399 |
| Aug | 87.9°F | 244 | 318 |
| Sep | 80.1°F | 83 | 108 |
| Oct | 66.7°F | 3 | 4 |
| Nov | 54.8°F | 0 | 0 |
| Dec | 45.9°F | 0 | 0 |
Jul alone uses 38% of the year's cooling energy. The unit runs the equivalent of 465 hours a year at full output.
Northglenn against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Thornton, CO | 2 mi | 96°F | 3 tons |
| Federal Heights, CO | 4 mi | 96°F | 3 tons |
| Broomfield, CO | 5 mi | 96°F | 3 tons |
| Westminster, CO | 5 mi | 96°F | 3 tons |
| Lafayette, CO | 8 mi | 96°F | 3 tons |
| Erie, CO | 9 mi | 96°F | 3 tons |
Of 53 Colorado cities here, Northglenn has the 16th highest cooling load. The range runs from Boulder at 15,700 BTU/hr to Grand Junction at 36,500.
Where Northglenn's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Denver-Stapleton, 11.9 miles from the center of Northglenn at 5,286 ft above sea level. That is close enough that the station's summers are Northglenn's summers.
14 other cities use the same station and get the same climate inputs. The closest to Northglenn: Thornton (2 mi away, 11.5 mi from the station), Federal Heights (4 mi away, 10.5 mi from the station), Broomfield (5 mi away, 16.3 mi from the station), Westminster (5 mi away, 13 mi from the station), Lafayette (8 mi away, 20.1 mi from the station). Northglenn is farther from the station than 4 of them.
The sun over Northglenn in late July
At 39.91°N, the noon sun on 21 July stands 70.5° above the horizon over Northglenn and the day runs 14 h 25 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
38,287 people live in Northglenn, the 24th largest of the 53 Colorado cities sized on this site. Coordinates used: 39.9116, -104.9821.
Northglenn AC sizing questions
What size AC does a 2,000 sq ft house in Northglenn, CO need?
About 3 tons, for a cooling load of 32,700 BTU/hr on a 96°F design day. That is one ton per 735 square feet in Northglenn's climate.
Is 20 BTU per square foot right for Northglenn?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Denver-Stapleton. For a single room here, plan on 16.3 BTU/hr per square foot.
What does central AC cost to run in Northglenn?
About $178 a year: 1,061 kWh at SEER2 14.3 and 16.8¢ per kWh, over 4 cooling months.