What size AC for North Ogden, UT? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in North Ogden needs
3 tons central AC or heat pump, about 35,600 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 18% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 674 square feet in this climate. For a single room, size by the room: 17.8 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Ogden Hinkley Airport (8.8 mi away). Jul is the hottest month, averaging a high of 91.3°F and a low of 64.8°F, with about 49 days a year at 90°F or more. That gives a design temperature of 97°F against 75°F inside.
What it costs to run
About 1,462 kWh a year at SEER2 14.3, or roughly $193 at Utah's average residential rate of 13.19¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in North Ogden
Of the 35,600 BTU/hr, 15,840 comes through walls, roof and windows on a 97°F afternoon (44%), 13,000 is sun on the house (37%), 2,120 is four people and their appliances, and 4,600 is moisture the coil has to wring out of North Ogden's summer air (13%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 30,960 BTU/hr before the moisture allowance.
Other house sizes in North Ogden
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,000 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,300 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 43,900 | 4 tons | 5 tons |
| 3,000 sq ft | 52,200 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,700 BTU/hr.
Month by month in North Ogden
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 35.7°F | 0 | 0 |
| Feb | 41.9°F | 0 | 0 |
| Mar | 52.7°F | 0 | 0 |
| Apr | 59.6°F | 2 | 3 |
| May | 70.1°F | 35 | 49 |
| Jun | 81.5°F | 162 | 225 |
| Jul | 91.3°F | 405 | 563 |
| Aug | 88.7°F | 339 | 472 |
| Sep | 77.8°F | 104 | 144 |
| Oct | 62.7°F | 5 | 7 |
| Nov | 48.5°F | 0 | 0 |
| Dec | 36.8°F | 0 | 0 |
Jul alone uses 39% of the year's cooling energy. The unit runs the equivalent of 587 hours a year at full output.
North Ogden against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Pleasant View, UT | 2 mi | 97°F | 3 tons |
| Ogden, UT | 6 mi | 97°F | 3 tons |
| West Haven, UT | 9 mi | 97°F | 3 tons |
| South Ogden, UT | 10 mi | 97°F | 3 tons |
| Roy, UT | 11 mi | 97°F | 3 tons |
| Clinton, UT | 13 mi | 97°F | 3 tons |
Of 67 Utah cities here, North Ogden has the 39th highest cooling load. The range runs from Heber at 30,700 BTU/hr to St. George at 49,200.
Where North Ogden's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Ogden Hinkley Airport, 8.8 miles from the center of North Ogden at 4,449 ft above sea level. That is close enough that the station's summers are North Ogden's summers.
11 other cities use the same station and get the same climate inputs. The closest to North Ogden: Pleasant View (2 mi away, 9.1 mi from the station), Ogden (6 mi away, 3.5 mi from the station), West Haven (9 mi away, 2.2 mi from the station), South Ogden (10 mi away, 3.4 mi from the station), Roy (11 mi away, 2.3 mi from the station). North Ogden is farther from the station than 9 of them.
The sun over North Ogden in late July
At 41.31°N, the noon sun on 21 July stands 69.1° above the horizon over North Ogden and the day runs 14 h 33 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
22,908 people live in North Ogden, the 45th largest of the 67 Utah cities sized on this site. Coordinates used: 41.3146, -111.9597.
North Ogden AC sizing questions
What size AC does a 2,000 sq ft house in North Ogden, UT need?
About 3 tons, for a cooling load of 35,600 BTU/hr on a 97°F design day. That is one ton per 674 square feet in North Ogden's climate.
Is 20 BTU per square foot right for North Ogden?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Ogden Hinkley Airport. For a single room here, plan on 17.8 BTU/hr per square foot.
What does central AC cost to run in North Ogden?
About $193 a year: 1,462 kWh at SEER2 14.3 and 13.19¢ per kWh, over 4 cooling months.