ACSizeCheck

What size AC for North Liberty, IA? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in North Liberty needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Iowa City Municipal Airport (8 mi away). Jul is the hottest month, averaging a high of 85.8°F and a low of 65.8°F, with about 19 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,452 kWh a year at SEER2 14.3, or roughly $211 at Iowa's average residential rate of 14.55¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in North Liberty

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of North Liberty's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in North Liberty

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in North Liberty

MonthAvg highCooling degree daysAC kWh
Jan30.9°F00
Feb35.5°F00
Mar49.5°F22
Apr62.6°F69
May73.4°F73102
Jun82.6°F233324
Jul85.8°F336467
Aug83.8°F269374
Sep77.5°F110153
Oct64.1°F1520
Nov49.2°F00
Dec36.3°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 696 hours a year at full output.

North Liberty against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Coralville, IA3 mi90°F2.5 tons
Iowa City, IA7 mi90°F2.5 tons
Cedar Rapids, IA16 mi87°F2 tons
Marion, IA21 mi87°F2 tons
Muscatine, IA36 mi90°F2.5 tons
Davenport, IA54 mi88°F2.5 tons

Of 41 Iowa cities here, North Liberty has the 15th highest cooling load. The range runs from Dubuque at 24,900 BTU/hr to Council Bluffs at 34,300.

Where North Liberty's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Iowa City Municipal Airport, 8 miles from the center of North Liberty at 652 ft above sea level. That is close enough that the station's summers are North Liberty's summers.

2 other cities use the same station and get the same climate inputs. The closest to North Liberty: Coralville (3 mi away, 4.9 mi from the station), Iowa City (7 mi away, 1.3 mi from the station). North Liberty is farther from the station than 2 of them.

The sun over North Liberty in late July

At 41.74°N, the noon sun on 21 July stands 68.7° above the horizon over North Liberty and the day runs 14 h 35 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

21,904 people live in North Liberty, the 27th largest of the 41 Iowa cities sized on this site. Coordinates used: 41.7436, -91.6112.

North Liberty AC sizing questions

What size AC does a 2,000 sq ft house in North Liberty, IA need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in North Liberty's climate.

Is 20 BTU per square foot right for North Liberty?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Iowa City Municipal Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in North Liberty?

About $211 a year: 1,452 kWh at SEER2 14.3 and 14.55¢ per kWh, over 5 cooling months.