ACSizeCheck

What size AC for Normal, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Normal needs

2.5 tons central AC or heat pump, about 28,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 46% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 834 square feet in this climate. For a single room, size by the room: 14.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Normal 4ne (3 mi away). Jul is the hottest month, averaging a high of 86°F and a low of 63°F, with about 26 days a year at 90°F or more. That gives a design temperature of 91°F against 75°F inside.

What it costs to run

About 1,276 kWh a year at SEER2 14.3, or roughly $245 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Normal

Of the 28,800 BTU/hr, 11,520 comes through walls, roof and windows on a 91°F afternoon (40%), 13,000 is sun on the house (45%), 2,120 is four people and their appliances, and 2,100 is moisture the coil has to wring out of Normal's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 26,640 BTU/hr before the moisture allowance.

Other house sizes in Normal

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft15,5001.5 tons2 tons
1,500 sq ft22,2002 tons2.5 tons
2,500 sq ft35,4003 tons5 tons
3,000 sq ft42,0004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,600 BTU/hr.

Month by month in Normal

MonthAvg highCooling degree daysAC kWh
Jan33.4°F00
Feb38.2°F00
Mar49.8°F22
Apr62.8°F811
May74°F7699
Jun83.3°F218284
Jul86°F297388
Aug84.4°F244318
Sep78.8°F114149
Oct65.6°F1823
Nov50.2°F01
Dec38.3°F00

Jul alone uses 30% of the year's cooling energy. The unit runs the equivalent of 634 hours a year at full output.

Normal against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Bloomington, IL3 mi91°F2.5 tons
Morton, IL26 mi91°F2.5 tons
Washington, IL26 mi91°F2.5 tons
East Peoria, IL31 mi91°F2.5 tons
Pontiac, IL31 mi89°F2.5 tons
Lincoln, IL32 mi90°F2.5 tons

Of 225 Illinois cities here, Normal has the 158th highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Normal's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Normal 4ne, 3 miles from the center of Normal at 790 ft above sea level. That is close enough that the station's summers are Normal's summers.

1 other city uses the same station and get the same climate inputs. The closest to Normal: Bloomington (3 mi away, 5.2 mi from the station). Normal sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Normal in late July

At 40.52°N, the noon sun on 21 July stands 69.9° above the horizon over Normal and the day runs 14 h 28 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

53,304 people live in Normal, the 27th largest of the 225 Illinois cities sized on this site. Coordinates used: 40.5201, -88.9922.

Normal AC sizing questions

What size AC does a 2,000 sq ft house in Normal, IL need?

About 2.5 tons, for a cooling load of 28,800 BTU/hr on a 91°F design day. That is one ton per 834 square feet in Normal's climate.

Is 20 BTU per square foot right for Normal?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Normal 4ne. For a single room here, plan on 14.4 BTU/hr per square foot.

What does central AC cost to run in Normal?

About $245 a year: 1,276 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.