ACSizeCheck

What size AC for New Port Richey, FL? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in New Port Richey needs

3.5 tons central AC or heat pump, about 41,200 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.4 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 583 square feet in this climate. For a single room, size by the room: 20.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Tarpon Springs Sewage Plt (6.9 mi away). Aug is the hottest month, averaging a high of 90.8°F and a low of 75.7°F, with about 95 days a year at 90°F or more. That gives a design temperature of 98°F against 75°F inside.

What it costs to run

About 5,475 kWh a year at SEER2 14.3, or roughly $839 at Florida's average residential rate of 15.32¢ per kWh. Cooling runs 11 months of the year here.

What drives the load in New Port Richey

Of the 41,200 BTU/hr, 16,560 comes through walls, roof and windows on a 98°F afternoon (40%), 13,000 is sun on the house (32%), 2,120 is four people and their appliances, and 9,500 is moisture the coil has to wring out of New Port Richey's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 31,680 BTU/hr before the moisture allowance.

Other house sizes in New Port Richey

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,0002 tons2 tons
1,500 sq ft31,6003 tons2.5 tons
2,500 sq ft50,8004 tons5 tons
3,000 sq ft60,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,100 BTU/hr; a 350 sq ft living room needs about 7,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,400 BTU/hr.

Month by month in New Port Richey

MonthAvg highCooling degree daysAC kWh
Jan69.3°F4265
Feb72°F5688
Mar76°F118185
Apr81.1°F224351
May86.2°F393617
Jun89.7°F511803
Jul90.6°F561881
Aug90.8°F566889
Sep88.9°F488766
Oct83.8°F334525
Nov76.3°F128202
Dec71.4°F66103

Aug alone uses 16% of the year's cooling energy. The unit runs the equivalent of 1,901 hours a year at full output.

New Port Richey against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Tarpon Springs, FL8 mi98°F3.5 tons
Oldsmar, FL14 mi98°F3.5 tons
Dunedin, FL15 mi98°F3.5 tons
Safety Harbor, FL17 mi98°F3.5 tons
Clearwater, FL19 mi98°F3.5 tons
Largo, FL24 mi98°F3.5 tons

Of 173 Florida cities here, New Port Richey has the 97th highest cooling load. The range runs from Miami Shores at 36,500 BTU/hr to Plant City at 44,900.

Where New Port Richey's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Tarpon Springs Sewage Plt, 6.9 miles from the center of New Port Richey at 6 ft above sea level. That is close enough that the station's summers are New Port Richey's summers.

1 other city uses the same station and get the same climate inputs. The closest to New Port Richey: Tarpon Springs (8 mi away, 1.6 mi from the station). New Port Richey is farther from the station than 1 of them.

The sun over New Port Richey in late July

At 28.25°N, the noon sun on 21 July stands 82.2° above the horizon over New Port Richey and the day runs 13 h 32 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

18,130 people live in New Port Richey, the 130th largest of the 173 Florida cities sized on this site. Coordinates used: 28.2466, -82.7175.

New Port Richey AC sizing questions

What size AC does a 2,000 sq ft house in New Port Richey, FL need?

About 3.5 tons, for a cooling load of 41,200 BTU/hr on a 98°F design day. That is one ton per 583 square feet in New Port Richey's climate.

Is 20 BTU per square foot right for New Port Richey?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Tarpon Springs Sewage Plt. For a single room here, plan on 20.6 BTU/hr per square foot.

What does central AC cost to run in New Port Richey?

About $839 a year: 5,475 kWh at SEER2 14.3 and 15.32¢ per kWh, over 11 cooling months.