ACSizeCheck

What size AC for New Iberia, LA? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in New Iberia needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at New Iberia Airport - Acadiana Regional (4.2 mi away). Aug is the hottest month, averaging a high of 92.4°F and a low of 74°F, with about 93 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 4,609 kWh a year at SEER2 14.3, or roughly $612 at Louisiana's average residential rate of 13.27¢ per kWh. Cooling runs 8 months of the year here.

What drives the load in New Iberia

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of New Iberia's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in New Iberia

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in New Iberia

MonthAvg highCooling degree daysAC kWh
Jan62.7°F1524
Feb66.5°F2540
Mar72.9°F65103
Apr79.2°F153241
May85.6°F347546
Jun90.2°F490770
Jul91.5°F555872
Aug92.4°F564886
Sep89°F437686
Oct81.8°F207325
Nov72°F4976
Dec65.1°F2640

Aug alone uses 19% of the year's cooling energy. The unit runs the equivalent of 1,565 hours a year at full output.

New Iberia against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Broussard, LA12 mi99°F4 tons
Youngsville, LA12 mi99°F4 tons
Abbeville, LA18 mi99°F4 tons
Lafayette, LA19 mi99°F4 tons
Carencro, LA25 mi99°F4 tons
Crowley, LA36 mi98°F3.5 tons

Of 35 Louisiana cities here, New Iberia has the 11th highest cooling load. The range runs from Covington at 37,800 BTU/hr to Natchitoches at 45,900.

Where New Iberia's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is New Iberia Airport - Acadiana Regional, 4.2 miles from the center of New Iberia at 16 ft above sea level. That is close enough that the station's summers are New Iberia's summers.

1 other city uses the same station and get the same climate inputs. The closest to New Iberia: Abbeville (18 mi away, 15 mi from the station). New Iberia sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over New Iberia in late July

At 30.01°N, the noon sun on 21 July stands 80.4° above the horizon over New Iberia and the day runs 13 h 39 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

26,849 people live in New Iberia, the 13th largest of the 35 Louisiana cities sized on this site. Coordinates used: 30.0055, -91.8203.

New Iberia AC sizing questions

What size AC does a 2,000 sq ft house in New Iberia, LA need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in New Iberia's climate.

Is 20 BTU per square foot right for New Iberia?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at New Iberia Airport - Acadiana Regional. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in New Iberia?

About $612 a year: 4,609 kWh at SEER2 14.3 and 13.27¢ per kWh, over 8 cooling months.