What size AC for New Hyde Park, NY? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in New Hyde Park needs
2.5 tons central AC or heat pump, about 29,900 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 804 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Jfk International Airport (7.6 mi away). Jul is the hottest month, averaging a high of 83.6°F and a low of 68.7°F, with about 11 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.
What it costs to run
About 1,499 kWh a year at SEER2 14.3, or roughly $438 at New York's average residential rate of 29.26¢ per kWh. Cooling runs 4 months of the year here.
What drives the load in New Hyde Park
Of the 29,900 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (31%), 13,000 is sun on the house (43%), 2,120 is four people and their appliances, and 5,400 is moisture the coil has to wring out of New Hyde Park's summer air (18%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.
Other house sizes in New Hyde Park
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 16,200 | 1.5 tons | 2 tons |
| 1,500 sq ft | 23,000 | 2 tons | 2.5 tons |
| 2,500 sq ft | 36,700 | 3.5 tons | 5 tons |
| 3,000 sq ft | 43,500 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.
Month by month in New Hyde Park
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 39.5°F | 0 | 0 |
| Feb | 41.7°F | 0 | 0 |
| Mar | 48.7°F | 0 | 0 |
| Apr | 58.8°F | 2 | 4 |
| May | 68.4°F | 30 | 45 |
| Jun | 78°F | 177 | 260 |
| Jul | 83.6°F | 346 | 510 |
| Aug | 82.2°F | 311 | 458 |
| Sep | 75.8°F | 135 | 199 |
| Oct | 64.7°F | 15 | 22 |
| Nov | 53.8°F | 0 | 0 |
| Dec | 44.5°F | 0 | 0 |
Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 718 hours a year at full output.
New Hyde Park against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Floral Park, NY | 1 mi | 88°F | 2.5 tons |
| Garden City, NY | 2 mi | 88°F | 2.5 tons |
| Mineola, NY | 3 mi | 88°F | 2.5 tons |
| Hempstead, NY | 4 mi | 88°F | 2.5 tons |
| Valley Stream, NY | 5 mi | 88°F | 2.5 tons |
| Lynbrook, NY | 5 mi | 88°F | 2.5 tons |
Of 90 New York cities here, New Hyde Park has the 17th highest cooling load. The range runs from Gloversville at 20,200 BTU/hr to Spring Valley at 33,400.
Where New Hyde Park's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Jfk International Airport, 7.6 miles from the center of New Hyde Park at 9 ft above sea level. That is close enough that the station's summers are New Hyde Park's summers.
10 other cities use the same station and get the same climate inputs. The closest to New Hyde Park: Floral Park (1 mi away, 6.6 mi from the station), Garden City (2 mi away, 8.6 mi from the station), Mineola (3 mi away, 9.9 mi from the station), Hempstead (4 mi away, 8.8 mi from the station), Valley Stream (5 mi away, 3.6 mi from the station). New Hyde Park is farther from the station than 6 of them.
The sun over New Hyde Park in late July
At 40.73°N, the noon sun on 21 July stands 69.7° above the horizon over New Hyde Park and the day runs 14 h 29 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
10,220 people live in New Hyde Park, the 87th largest of the 90 New York cities sized on this site. Coordinates used: 40.7323, -73.6859.
New Hyde Park AC sizing questions
What size AC does a 2,000 sq ft house in New Hyde Park, NY need?
About 2.5 tons, for a cooling load of 29,900 BTU/hr on a 88°F design day. That is one ton per 804 square feet in New Hyde Park's climate.
Is 20 BTU per square foot right for New Hyde Park?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Jfk International Airport. For a single room here, plan on 14.9 BTU/hr per square foot.
What does central AC cost to run in New Hyde Park?
About $438 a year: 1,499 kWh at SEER2 14.3 and 29.26¢ per kWh, over 4 cooling months.