ACSizeCheck

What size AC for New Albany, IN? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in New Albany needs

3 tons central AC or heat pump, about 34,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 23% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 701 square feet in this climate. For a single room, size by the room: 17.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Louisville Bowman Field (10.4 mi away). Jul is the hottest month, averaging a high of 87.9°F and a low of 69.3°F, with about 38 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.

What it costs to run

About 2,275 kWh a year at SEER2 14.3, or roughly $388 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in New Albany

Of the 34,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (38%), 13,000 is sun on the house (38%), 2,120 is four people and their appliances, and 6,200 is moisture the coil has to wring out of New Albany's summer air (18%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.

Other house sizes in New Albany

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft18,4001.5 tons2 tons
1,500 sq ft26,3002.5 tons2.5 tons
2,500 sq ft42,2004 tons5 tons
3,000 sq ft50,1004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,300 BTU/hr.

Month by month in New Albany

MonthAvg highCooling degree daysAC kWh
Jan42.9°F00
Feb47.5°F01
Mar57°F710
Apr68.6°F3653
May77.1°F140207
Jun84.8°F313462
Jul87.9°F422622
Aug87.1°F391576
Sep80.9°F194285
Oct69.3°F3857
Nov56.6°F23
Dec46.4°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 950 hours a year at full output.

New Albany against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Clarksville, IN3 mi93°F3 tons
Sellersburg, IN7 mi93°F3 tons
Jeffersonville, IN7 mi93°F3 tons
Shively, KY8 mi94°F3 tons
St. Matthews, KY11 mi93°F3 tons
Lyndon, KY13 mi93°F3 tons

Of 88 Indiana cities here, New Albany has the 4th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where New Albany's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Louisville Bowman Field, across the line in Kentucky, 10.4 miles from the center of New Albany at 540 ft above sea level. That is close enough that the station's summers are New Albany's summers.

7 other cities use the same station and get the same climate inputs. The closest to New Albany: Clarksville (3 mi away, 8.5 mi from the station), Sellersburg (7 mi away, 13.2 mi from the station), Jeffersonville (7 mi away, 7.7 mi from the station), St. Matthews (11 mi away, 1.9 mi from the station), Lyndon (13 mi away, 4.7 mi from the station). New Albany is farther from the station than 6 of them.

The sun over New Albany in late July

At 38.31°N, the noon sun on 21 July stands 72.1° above the horizon over New Albany and the day runs 14 h 17 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

37,652 people live in New Albany, the 26th largest of the 88 Indiana cities sized on this site. Coordinates used: 38.3122, -85.8240.

New Albany AC sizing questions

What size AC does a 2,000 sq ft house in New Albany, IN need?

About 3 tons, for a cooling load of 34,300 BTU/hr on a 93°F design day. That is one ton per 701 square feet in New Albany's climate.

Is 20 BTU per square foot right for New Albany?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Louisville Bowman Field. For a single room here, plan on 17.1 BTU/hr per square foot.

What does central AC cost to run in New Albany?

About $388 a year: 2,275 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.