What size AC for Neosho, MO? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Neosho needs
3 tons central AC or heat pump, about 36,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Neosho (1.6 mi away). Jul is the hottest month, averaging a high of 89.8°F and a low of 70.4°F, with about 41 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.
What it costs to run
About 2,476 kWh a year at SEER2 14.3, or roughly $354 at Missouri's average residential rate of 14.28¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Neosho
Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Neosho's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.
Other house sizes in Neosho
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,700 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 44,400 | 4 tons | 5 tons |
| 3,000 sq ft | 52,700 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.
Month by month in Neosho
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 46.3°F | 0 | 0 |
| Feb | 50.9°F | 1 | 1 |
| Mar | 60°F | 9 | 13 |
| Apr | 69.7°F | 41 | 60 |
| May | 77.2°F | 138 | 204 |
| Jun | 85.2°F | 326 | 480 |
| Jul | 89.8°F | 468 | 690 |
| Aug | 89.4°F | 430 | 634 |
| Sep | 82.2°F | 213 | 314 |
| Oct | 71.5°F | 48 | 70 |
| Nov | 59.5°F | 5 | 8 |
| Dec | 49.4°F | 1 | 1 |
Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 983 hours a year at full output.
Neosho against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Joplin, MO | 17 mi | 96°F | 3.5 tons |
| Webb City, MO | 21 mi | 96°F | 3.5 tons |
| Carthage, MO | 21 mi | 96°F | 3.5 tons |
| Monett, MO | 25 mi | 94°F | 3 tons |
| Bella Vista, AR | 27 mi | 96°F | 3.5 tons |
| Miami, OK | 27 mi | 97°F | 3 tons |
Of 80 Missouri cities here, Neosho has the 36th highest cooling load. The range runs from Hannibal at 30,600 BTU/hr to Sikeston at 37,800.
Where Neosho's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Neosho, 1.6 miles from the center of Neosho at 1,033 ft above sea level. That is close enough that the station's summers are Neosho's summers.
No other city in this set uses Neosho, so this sizing is Neosho's alone.
The sun over Neosho in late July
At 36.85°N, the noon sun on 21 July stands 73.6° above the horizon over Neosho and the day runs 14 h 09 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
13,782 people live in Neosho, the 57th largest of the 80 Missouri cities sized on this site. Coordinates used: 36.8455, -94.3764.
Neosho AC sizing questions
What size AC does a 2,000 sq ft house in Neosho, MO need?
About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Neosho's climate.
Is 20 BTU per square foot right for Neosho?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Neosho. For a single room here, plan on 18 BTU/hr per square foot.
What does central AC cost to run in Neosho?
About $354 a year: 2,476 kWh at SEER2 14.3 and 14.28¢ per kWh, over 5 cooling months.