ACSizeCheck

What size AC for Moraga, CA? 1.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Moraga needs

1.5 tons central AC or heat pump, about 18,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 134% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 1.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,335 square feet in this climate. For a single room, size by the room: 9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Oakland International Airport (10.7 mi away). Sep is the hottest month, averaging a high of 74.1°F and a low of 55.5°F, with about 6 days a year at 90°F or more. That gives a design temperature of 78°F against 75°F inside.

What it costs to run

About 220 kWh a year at SEER2 14.3, or roughly $72 at California's average residential rate of 32.58¢ per kWh. Cooling runs 1 month of the year here.

What drives the load in Moraga

Of the 18,000 BTU/hr, 2,160 comes through walls, roof and windows on a 78°F afternoon (12%), 13,000 is sun on the house (72%), 2,120 is four people and their appliances, and 700 is moisture the coil has to wring out of Moraga's summer air (4%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 17,280 BTU/hr before the moisture allowance.

Other house sizes in Moraga

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft10,1001.5 tons2 tons
1,500 sq ft14,0001.5 tons2.5 tons
2,500 sq ft21,9002 tons5 tons
3,000 sq ft25,9002 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,400 BTU/hr; a 350 sq ft living room needs about 3,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 5,400 BTU/hr.

Month by month in Moraga

MonthAvg highCooling degree daysAC kWh
Jan57.7°F00
Feb60.3°F00
Mar63.1°F11
Apr65.6°F45
May67.9°F1215
Jun71.4°F2430
Jul71.6°F2531
Aug72.4°F3949
Sep74.1°F5063
Oct71.5°F2025
Nov63.9°F11
Dec57.9°F00

Sep alone uses 29% of the year's cooling energy. The unit runs the equivalent of 175 hours a year at full output.

Moraga against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lafayette, CA3 mi94°F2.5 tons
Orinda, CA4 mi94°F2.5 tons
Walnut Creek, CA6 mi94°F2.5 tons
Piedmont, CA6 mi78°F1.5 tons
Oakland, CA8 mi78°F1.5 tons
Pleasant Hill, CA8 mi94°F2.5 tons

Of 376 California cities here, Moraga has the 355th highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Moraga's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Oakland International Airport, 10.7 miles from the center of Moraga at 5 ft above sea level. That is close enough that the station's summers are Moraga's summers.

3 other cities use the same station and get the same climate inputs. The closest to Moraga: Piedmont (6 mi away, 7.2 mi from the station), Oakland (8 mi away, 3.6 mi from the station), Alameda (10 mi away, 2.2 mi from the station). Moraga is farther from the station than 3 of them.

The sun over Moraga in late July

At 37.85°N, the noon sun on 21 July stands 72.6° above the horizon over Moraga and the day runs 14 h 14 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,698 people live in Moraga, the 319th largest of the 376 California cities sized on this site. Coordinates used: 37.8457, -122.1232.

Moraga AC sizing questions

What size AC does a 2,000 sq ft house in Moraga, CA need?

About 1.5 tons, for a cooling load of 18,000 BTU/hr on a 78°F design day. That is one ton per 1,335 square feet in Moraga's climate.

Is 20 BTU per square foot right for Moraga?

The chart gives 3.5 tons for 2,000 sq ft, against 1.5 tons sized from NOAA's 1991 to 2020 normals at Oakland International Airport. For a single room here, plan on 9 BTU/hr per square foot.

What does central AC cost to run in Moraga?

About $72 a year: 220 kWh at SEER2 14.3 and 32.58¢ per kWh, over 1 cooling month.