ACSizeCheck

What size AC for Mont Belvieu, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Mont Belvieu needs

4 tons central AC or heat pump, about 42,100 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.5 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 570 square feet in this climate. For a single room, size by the room: 21.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Baytown (8.3 mi away). Aug is the hottest month, averaging a high of 92.3°F and a low of 74.3°F, with about 84 days a year at 90°F or more. That gives a design temperature of 99°F against 75°F inside.

What it costs to run

About 4,443 kWh a year at SEER2 14.3, or roughly $712 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Mont Belvieu

Of the 42,100 BTU/hr, 17,280 comes through walls, roof and windows on a 99°F afternoon (41%), 13,000 is sun on the house (31%), 2,120 is four people and their appliances, and 9,700 is moisture the coil has to wring out of Mont Belvieu's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 32,400 BTU/hr before the moisture allowance.

Other house sizes in Mont Belvieu

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft22,4002 tons2 tons
1,500 sq ft32,3003 tons2.5 tons
2,500 sq ft52,0004 tons5 tons
3,000 sq ft61,8005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,200 BTU/hr; a 350 sq ft living room needs about 7,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 12,700 BTU/hr.

Month by month in Mont Belvieu

MonthAvg highCooling degree daysAC kWh
Jan62.9°F914
Feb66.4°F1523
Mar72.1°F5484
Apr77.5°F132208
May84.2°F326512
Jun89.2°F478752
Jul91.5°F560879
Aug92.3°F567891
Sep88.5°F413649
Oct81.6°F204321
Nov71.4°F5383
Dec64.5°F1726

Aug alone uses 20% of the year's cooling energy. The unit runs the equivalent of 1,508 hours a year at full output.

Mont Belvieu against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Baytown, TX8 mi101°F4 tons
La Porte, TX16 mi101°F4 tons
Deer Park, TX18 mi101°F4 tons
Seabrook, TX19 mi101°F4 tons
Pasadena, TX21 mi101°F4 tons
Galena Park, TX23 mi101°F4 tons

Of 252 Texas cities here, Mont Belvieu has the 233rd highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Mont Belvieu's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Baytown, 8.3 miles from the center of Mont Belvieu at 26 ft above sea level. That is close enough that the station's summers are Mont Belvieu's summers.

No other city in this set uses Baytown, so this sizing is Mont Belvieu's alone.

The sun over Mont Belvieu in late July

At 29.85°N, the noon sun on 21 July stands 80.5° above the horizon over Mont Belvieu and the day runs 13 h 39 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

10,229 people live in Mont Belvieu, the 243rd largest of the 252 Texas cities sized on this site. Coordinates used: 29.8500, -94.8747.

Mont Belvieu AC sizing questions

What size AC does a 2,000 sq ft house in Mont Belvieu, TX need?

About 4 tons, for a cooling load of 42,100 BTU/hr on a 99°F design day. That is one ton per 570 square feet in Mont Belvieu's climate.

Is 20 BTU per square foot right for Mont Belvieu?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Baytown. For a single room here, plan on 21.1 BTU/hr per square foot.

What does central AC cost to run in Mont Belvieu?

About $712 a year: 4,443 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.