What size AC for Mishawaka, IN? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Mishawaka needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at S Bend Airport (8.1 mi away). Jul is the hottest month, averaging a high of 82.7°F and a low of 62.1°F, with about 14 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 942 kWh a year at SEER2 14.3, or roughly $161 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Mishawaka

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Mishawaka's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Mishawaka

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Mishawaka

MonthAvg highCooling degree daysAC kWh
Jan31.2°F00
Feb34.9°F00
Mar46.2°F22
Apr59°F67
May70.1°F4863
Jun79.4°F156204
Jul82.7°F236308
Aug80.8°F189246
Sep74.4°F77100
Oct61.8°F912
Nov47.7°F00
Dec36.3°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 525 hours a year at full output.

Mishawaka against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
South Bend, IN5 mi87°F2 tons
Elkhart, IN11 mi88°F2.5 tons
Niles, MI12 mi87°F2 tons
Goshen, IN19 mi88°F2.5 tons
Plymouth, IN24 mi88°F2.5 tons
La Porte, IN29 mi86°F2.5 tons

Of 88 Indiana cities here, Mishawaka has the 83rd highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Mishawaka's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is S Bend Airport, 8.1 miles from the center of Mishawaka at 772 ft above sea level. That is close enough that the station's summers are Mishawaka's summers.

2 other cities use the same station and get the same climate inputs. The closest to Mishawaka: South Bend (5 mi away, 3.2 mi from the station), Niles (12 mi away, 9.5 mi from the station). Mishawaka is farther from the station than 1 of them.

The sun over Mishawaka in late July

At 41.68°N, the noon sun on 21 July stands 68.7° above the horizon over Mishawaka and the day runs 14 h 35 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

51,020 people live in Mishawaka, the 21st largest of the 88 Indiana cities sized on this site. Coordinates used: 41.6766, -86.1654.

Mishawaka AC sizing questions

What size AC does a 2,000 sq ft house in Mishawaka, IN need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Mishawaka's climate.

Is 20 BTU per square foot right for Mishawaka?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at S Bend Airport. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Mishawaka?

About $161 a year: 942 kWh at SEER2 14.3 and 17.04¢ per kWh, over 4 cooling months.