What size AC for Mexico, MO? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Mexico needs
3 tons central AC or heat pump, about 32,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 30% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 743 square feet in this climate. For a single room, size by the room: 16.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Mexico (0.6 mi away). Jul is the hottest month, averaging a high of 87.9°F and a low of 67.3°F, with about 38 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.
What it costs to run
About 1,772 kWh a year at SEER2 14.3, or roughly $253 at Missouri's average residential rate of 14.28¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Mexico
Of the 32,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (40%), 13,000 is sun on the house (40%), 2,120 is four people and their appliances, and 4,200 is moisture the coil has to wring out of Mexico's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.
Other house sizes in Mexico
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 17,400 | 1.5 tons | 2 tons |
| 1,500 sq ft | 24,800 | 2 tons | 2.5 tons |
| 2,500 sq ft | 39,800 | 3.5 tons | 5 tons |
| 3,000 sq ft | 47,200 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,400 BTU/hr; a 350 sq ft living room needs about 5,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 9,700 BTU/hr.
Month by month in Mexico
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 37.6°F | 0 | 0 |
| Feb | 42.7°F | 0 | 0 |
| Mar | 54.2°F | 4 | 6 |
| Apr | 65.9°F | 21 | 30 |
| May | 75.1°F | 92 | 127 |
| Jun | 83.9°F | 261 | 362 |
| Jul | 87.9°F | 391 | 543 |
| Aug | 86.6°F | 337 | 469 |
| Sep | 79.4°F | 145 | 201 |
| Oct | 67.6°F | 23 | 32 |
| Nov | 54.3°F | 1 | 1 |
| Dec | 41.9°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 785 hours a year at full output.
Mexico against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Fulton, MO | 22 mi | 94°F | 3 tons |
| Columbia, MO | 29 mi | 94°F | 3 tons |
| Moberly, MO | 35 mi | 92°F | 3 tons |
| Jefferson City, MO | 44 mi | 94°F | 3 tons |
| Hannibal, MO | 46 mi | 91°F | 2.5 tons |
| Troy, MO | 50 mi | 95°F | 3 tons |
Of 80 Missouri cities here, Mexico has the 74th highest cooling load. The range runs from Hannibal at 30,600 BTU/hr to Sikeston at 37,800.
Where Mexico's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Mexico, 0.6 miles from the center of Mexico at 760 ft above sea level. That is close enough that the station's summers are Mexico's summers.
No other city in this set uses Mexico, so this sizing is Mexico's alone.
The sun over Mexico in late July
At 39.16°N, the noon sun on 21 July stands 71.2° above the horizon over Mexico and the day runs 14 h 21 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
11,482 people live in Mexico, the 71st largest of the 80 Missouri cities sized on this site. Coordinates used: 39.1622, -91.8728.
Mexico AC sizing questions
What size AC does a 2,000 sq ft house in Mexico, MO need?
About 3 tons, for a cooling load of 32,300 BTU/hr on a 93°F design day. That is one ton per 743 square feet in Mexico's climate.
Is 20 BTU per square foot right for Mexico?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Mexico. For a single room here, plan on 16.1 BTU/hr per square foot.
What does central AC cost to run in Mexico?
About $253 a year: 1,772 kWh at SEER2 14.3 and 14.28¢ per kWh, over 5 cooling months.