What size AC for Mesquite, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Mesquite needs

4 tons central AC or heat pump, about 47,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Dallas FAA Airport (15.6 mi away). Aug is the hottest month, averaging a high of 97.1°F and a low of 77.4°F, with about 108 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 4,909 kWh a year at SEER2 14.3, or roughly $787 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Mesquite

Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of Mesquite's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Mesquite

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft25,2002 tons2 tons
1,500 sq ft36,5003 tons2.5 tons
2,500 sq ft59,0005 tons5 tons
3,000 sq ft70,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.

Month by month in Mesquite

MonthAvg highCooling degree daysAC kWh
Jan57.7°F45
Feb62°F1117
Mar69.9°F4774
Apr77.4°F128201
May84.9°F330519
Jun92.7°F548860
Jul96.9°F6911,086
Aug97.1°F6901,083
Sep90°F454713
Oct79.5°F183287
Nov67.8°F3454
Dec59.2°F610

Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,470 hours a year at full output.

Mesquite against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Balch Springs, TX4 mi104°F4 tons
Seagoville, TX8 mi104°F4 tons
Forney, TX8 mi104°F4 tons
Heath, TX10 mi104°F4 tons
Garland, TX11 mi105°F4 tons
Dallas, TX11 mi105°F4 tons

Of 252 Texas cities here, Mesquite has the 34th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Mesquite's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Dallas FAA Airport, 15.6 miles from the center of Mesquite at 484 ft above sea level. That is close enough that the station's summers are Mesquite's summers.

7 other cities use the same station and get the same climate inputs. The closest to Mesquite: Garland (11 mi away, 12.9 mi from the station), Dallas (11 mi away, 5.1 mi from the station), Rowlett (11 mi away, 17.5 mi from the station), University Park (14 mi away, 2.5 mi from the station), Richardson (16 mi away, 11.9 mi from the station). Mesquite is farther from the station than 6 of them.

The sun over Mesquite in late July

At 32.76°N, the noon sun on 21 July stands 77.6° above the horizon over Mesquite and the day runs 13 h 51 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

150,140 people live in Mesquite, the 21st largest of the 252 Texas cities sized on this site. Coordinates used: 32.7595, -96.5842.

Mesquite AC sizing questions

What size AC does a 2,000 sq ft house in Mesquite, TX need?

About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in Mesquite's climate.

Is 20 BTU per square foot right for Mesquite?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Dallas FAA Airport. For a single room here, plan on 23.9 BTU/hr per square foot.

What does central AC cost to run in Mesquite?

About $787 a year: 4,909 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.