ACSizeCheck

What size AC for Menomonie, WI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Menomonie needs

2 tons central AC or heat pump, about 24,900 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 69% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 965 square feet in this climate. For a single room, size by the room: 12.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Menomonie (1.6 mi away). Jul is the hottest month, averaging a high of 82°F and a low of 59.2°F, with about 8 days a year at 90°F or more. That gives a design temperature of 86°F against 75°F inside.

What it costs to run

About 650 kWh a year at SEER2 14.3, or roughly $124 at Wisconsin's average residential rate of 19.05¢ per kWh. Cooling runs 3 months of the year here.

What drives the load in Menomonie

Of the 24,900 BTU/hr, 7,920 comes through walls, roof and windows on a 86°F afternoon (32%), 13,000 is sun on the house (52%), 2,120 is four people and their appliances, and 1,800 is moisture the coil has to wring out of Menomonie's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,040 BTU/hr before the moisture allowance.

Other house sizes in Menomonie

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,6001.5 tons2 tons
1,500 sq ft19,2001.5 tons2.5 tons
2,500 sq ft30,5002.5 tons5 tons
3,000 sq ft36,2003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,400 BTU/hr.

Month by month in Menomonie

MonthAvg highCooling degree daysAC kWh
Jan24°F00
Feb29.4°F00
Mar41.9°F00
Apr56.4°F23
May68.2°F2128
Jun77.9°F104136
Jul82°F188245
Aug79.9°F134175
Sep72.2°F4559
Oct58.9°F34
Nov42.7°F00
Dec29.2°F00

Jul alone uses 38% of the year's cooling energy. The unit runs the equivalent of 373 hours a year at full output.

Menomonie against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Eau Claire, WI21 mi87°F2 tons
Chippewa Falls, WI26 mi87°F2 tons
River Falls, WI35 mi86°F2 tons
New Richmond, WI35 mi87°F2.5 tons
Red Wing, MN40 mi87°F2 tons
Hudson, WI40 mi87°F2.5 tons

Of 98 Wisconsin cities here, Menomonie has the 55th highest cooling load. The range runs from Two Rivers at 20,200 BTU/hr to La Crosse at 29,800.

Where Menomonie's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Menomonie, 1.6 miles from the center of Menomonie at 795 ft above sea level. That is close enough that the station's summers are Menomonie's summers.

No other city in this set uses Menomonie, so this sizing is Menomonie's alone.

The sun over Menomonie in late July

At 44.89°N, the noon sun on 21 July stands 65.5° above the horizon over Menomonie and the day runs 14 h 54 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

16,709 people live in Menomonie, the 54th largest of the 98 Wisconsin cities sized on this site. Coordinates used: 44.8892, -91.9096.

Menomonie AC sizing questions

What size AC does a 2,000 sq ft house in Menomonie, WI need?

About 2 tons, for a cooling load of 24,900 BTU/hr on a 86°F design day. That is one ton per 965 square feet in Menomonie's climate.

Is 20 BTU per square foot right for Menomonie?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Menomonie. For a single room here, plan on 12.4 BTU/hr per square foot.

What does central AC cost to run in Menomonie?

About $124 a year: 650 kWh at SEER2 14.3 and 19.05¢ per kWh, over 3 cooling months.