ACSizeCheck

What size AC for McKinney, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in McKinney needs

4 tons central AC or heat pump, about 45,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.8 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 523 square feet in this climate. For a single room, size by the room: 22.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Mckinney Municipal Airport (4.5 mi away). Aug is the hottest month, averaging a high of 95.5°F and a low of 73.1°F, with about 97 days a year at 90°F or more. That gives a design temperature of 103°F against 75°F inside.

What it costs to run

About 3,976 kWh a year at SEER2 14.3, or roughly $637 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in McKinney

Of the 45,900 BTU/hr, 20,160 comes through walls, roof and windows on a 103°F afternoon (44%), 13,000 is sun on the house (28%), 2,120 is four people and their appliances, and 10,600 is moisture the coil has to wring out of McKinney's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 35,280 BTU/hr before the moisture allowance.

Other house sizes in McKinney

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft24,3002 tons2 tons
1,500 sq ft35,1003 tons2.5 tons
2,500 sq ft56,6005 tons5 tons
3,000 sq ft67,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 8,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,700 BTU/hr.

Month by month in McKinney

MonthAvg highCooling degree daysAC kWh
Jan55.5°F23
Feb59.7°F69
Mar67.5°F2540
Apr74.7°F77121
May82.8°F251394
Jun90.7°F463728
Jul95°F601945
Aug95.5°F598940
Sep88.3°F362568
Oct77.9°F123193
Nov66.2°F2031
Dec57.1°F46

Jul alone uses 24% of the year's cooling energy. The unit runs the equivalent of 1,240 hours a year at full output.

McKinney against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Fairview, TX5 mi103°F4 tons
Allen, TX7 mi103°F4 tons
Melissa, TX9 mi103°F4 tons
Prosper, TX9 mi103°F4 tons
Princeton, TX9 mi103°F4 tons
Frisco, TX10 mi103°F4 tons

Of 252 Texas cities here, McKinney has the 118th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where McKinney's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Mckinney Municipal Airport, 4.5 miles from the center of McKinney at 569 ft above sea level. That is close enough that the station's summers are McKinney's summers.

12 other cities use the same station and get the same climate inputs. The closest to McKinney: Fairview (5 mi away, 3.2 mi from the station), Allen (7 mi away, 7.2 mi from the station), Melissa (9 mi away, 7.5 mi from the station), Prosper (9 mi away, 13.2 mi from the station), Princeton (9 mi away, 4.7 mi from the station). McKinney is farther from the station than 1 of them.

The sun over McKinney in late July

At 33.20°N, the noon sun on 21 July stands 77.2° above the horizon over McKinney and the day runs 13 h 53 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

227,526 people live in McKinney, the 15th largest of the 252 Texas cities sized on this site. Coordinates used: 33.2011, -96.6642.

McKinney AC sizing questions

What size AC does a 2,000 sq ft house in McKinney, TX need?

About 4 tons, for a cooling load of 45,900 BTU/hr on a 103°F design day. That is one ton per 523 square feet in McKinney's climate.

Is 20 BTU per square foot right for McKinney?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Mckinney Municipal Airport. For a single room here, plan on 22.9 BTU/hr per square foot.

What does central AC cost to run in McKinney?

About $637 a year: 3,976 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.