ACSizeCheck

What size AC for Massillon, OH? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Massillon needs

2.5 tons central AC or heat pump, about 27,200 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 882 square feet in this climate. For a single room, size by the room: 13.6 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Akron Canton Airport (10.2 mi away). Jul is the hottest month, averaging a high of 84.3°F and a low of 63.4°F, with about 11 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.

What it costs to run

About 1,135 kWh a year at SEER2 14.3, or roughly $213 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Massillon

Of the 27,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (37%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Massillon's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.

Other house sizes in Massillon

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,8001.5 tons2 tons
1,500 sq ft21,0002 tons2.5 tons
2,500 sq ft33,4003 tons5 tons
3,000 sq ft39,7003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.

Month by month in Massillon

MonthAvg highCooling degree daysAC kWh
Jan35.5°F00
Feb38.6°F00
Mar48.4°F12
Apr61.8°F811
May72.3°F6483
Jun80.4°F177231
Jul84.3°F277361
Aug82.7°F233304
Sep75.9°F96125
Oct63.4°F1317
Nov50.7°F01
Dec39.9°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 596 hours a year at full output.

Massillon against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Canton, OH8 mi89°F2.5 tons
North Canton, OH9 mi89°F2.5 tons
Green, OH12 mi89°F2.5 tons
New Franklin, OH12 mi89°F2.5 tons
Barberton, OH16 mi90°F2.5 tons
Dover, OH18 mi88°F2.5 tons

Of 176 Ohio cities here, Massillon has the 109th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.

Where Massillon's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Akron Canton Airport, 10.2 miles from the center of Massillon at 1,210 ft above sea level. That is close enough that the station's summers are Massillon's summers.

5 other cities use the same station and get the same climate inputs. The closest to Massillon: Canton (8 mi away, 8.6 mi from the station), North Canton (9 mi away, 3.9 mi from the station), Green (12 mi away, 2.9 mi from the station), New Franklin (12 mi away, 7.8 mi from the station), Alliance (23 mi away, 16.9 mi from the station). Massillon is farther from the station than 4 of them.

The sun over Massillon in late July

At 40.78°N, the noon sun on 21 July stands 69.6° above the horizon over Massillon and the day runs 14 h 30 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

32,750 people live in Massillon, the 46th largest of the 176 Ohio cities sized on this site. Coordinates used: 40.7845, -81.5252.

Massillon AC sizing questions

What size AC does a 2,000 sq ft house in Massillon, OH need?

About 2.5 tons, for a cooling load of 27,200 BTU/hr on a 89°F design day. That is one ton per 882 square feet in Massillon's climate.

Is 20 BTU per square foot right for Massillon?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Akron Canton Airport. For a single room here, plan on 13.6 BTU/hr per square foot.

What does central AC cost to run in Massillon?

About $213 a year: 1,135 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.