ACSizeCheck

What size AC for Manvel, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Manvel needs

4 tons central AC or heat pump, about 44,000 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 546 square feet in this climate. For a single room, size by the room: 22 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Houston Clover Field (7.7 mi away). Aug is the hottest month, averaging a high of 94°F and a low of 76.2°F, with about 101 days a year at 90°F or more. That gives a design temperature of 101°F against 75°F inside.

What it costs to run

About 5,331 kWh a year at SEER2 14.3, or roughly $855 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Manvel

Of the 44,000 BTU/hr, 18,720 comes through walls, roof and windows on a 101°F afternoon (43%), 13,000 is sun on the house (30%), 2,120 is four people and their appliances, and 10,200 is moisture the coil has to wring out of Manvel's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 33,840 BTU/hr before the moisture allowance.

Other house sizes in Manvel

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft23,4002 tons2 tons
1,500 sq ft33,7003 tons2.5 tons
2,500 sq ft54,3005 tons5 tons
3,000 sq ft64,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,300 BTU/hr; a 350 sq ft living room needs about 7,700 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,200 BTU/hr.

Month by month in Manvel

MonthAvg highCooling degree daysAC kWh
Jan64.6°F2133
Feb68.3°F3961
Mar74°F94148
Apr79.5°F189297
May86°F396622
Jun91.4°F550865
Jul93.3°F612962
Aug94°F623979
Sep89.9°F483759
Oct82.9°F268421
Nov73.3°F83130
Dec66.4°F3555

Aug alone uses 18% of the year's cooling energy. The unit runs the equivalent of 1,733 hours a year at full output.

Manvel against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Iowa Colony, TX5 mi101°F4 tons
Pearland, TX5 mi101°F4 tons
Alvin, TX10 mi101°F4 tons
Friendswood, TX10 mi101°F4 tons
Missouri City, TX12 mi103°F4 tons
South Houston, TX14 mi101°F4 tons

Of 252 Texas cities here, Manvel has the 190th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Manvel's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Houston Clover Field, 7.7 miles from the center of Manvel at 39 ft above sea level. That is close enough that the station's summers are Manvel's summers.

9 other cities use the same station and get the same climate inputs. The closest to Manvel: Iowa Colony (5 mi away, 12.2 mi from the station), Pearland (5 mi away, 5.5 mi from the station), Alvin (10 mi away, 6.6 mi from the station), Friendswood (10 mi away, 2.6 mi from the station), Webster (15 mi away, 7.6 mi from the station). Manvel is farther from the station than 4 of them.

The sun over Manvel in late July

At 29.49°N, the noon sun on 21 July stands 80.9° above the horizon over Manvel and the day runs 13 h 37 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

19,309 people live in Manvel, the 160th largest of the 252 Texas cities sized on this site. Coordinates used: 29.4882, -95.3650.

Manvel AC sizing questions

What size AC does a 2,000 sq ft house in Manvel, TX need?

About 4 tons, for a cooling load of 44,000 BTU/hr on a 101°F design day. That is one ton per 546 square feet in Manvel's climate.

Is 20 BTU per square foot right for Manvel?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Houston Clover Field. For a single room here, plan on 22 BTU/hr per square foot.

What does central AC cost to run in Manvel?

About $855 a year: 5,331 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.