ACSizeCheck

What size AC for Lynwood, CA? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lynwood needs

2 tons central AC or heat pump, about 24,000 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 75% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 1,000 square feet in this climate. For a single room, size by the room: 12 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Hawthorne Municipal Airport (7.5 mi away). Aug is the hottest month, averaging a high of 78.7°F and a low of 65.3°F, with about 9 days a year at 90°F or more. That gives a design temperature of 83°F against 75°F inside.

What it costs to run

About 1,286 kWh a year at SEER2 14.3, or roughly $419 at California's average residential rate of 32.58¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Lynwood

Of the 24,000 BTU/hr, 5,760 comes through walls, roof and windows on a 83°F afternoon (24%), 13,000 is sun on the house (54%), 2,120 is four people and their appliances, and 3,100 is moisture the coil has to wring out of Lynwood's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 20,880 BTU/hr before the moisture allowance.

Other house sizes in Lynwood

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft13,2001.5 tons2 tons
1,500 sq ft18,6001.5 tons2.5 tons
2,500 sq ft29,4002.5 tons5 tons
3,000 sq ft34,8003 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,800 BTU/hr; a 350 sq ft living room needs about 4,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,200 BTU/hr.

Month by month in Lynwood

MonthAvg highCooling degree daysAC kWh
Jan67.3°F79
Feb66.8°F913
Mar67.8°F1622
Apr69.7°F2737
May70.7°F3448
Jun73.1°F77107
Jul77.2°F185257
Aug78.7°F217302
Sep78.5°F196272
Oct76°F120167
Nov71.7°F3548
Dec66.4°F33

Aug alone uses 23% of the year's cooling energy. The unit runs the equivalent of 766 hours a year at full output.

Lynwood against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
South Gate, CA1 mi89°F2.5 tons
Compton, CA3 mi83°F2 tons
Paramount, CA3 mi88°F2.5 tons
Cudahy, CA3 mi89°F2.5 tons
Bell Gardens, CA4 mi89°F2.5 tons
Huntington Park, CA4 mi89°F2.5 tons

Of 376 California cities here, Lynwood has the 268th highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Lynwood's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Hawthorne Municipal Airport, 7.5 miles from the center of Lynwood at 55 ft above sea level. That is close enough that the station's summers are Lynwood's summers.

5 other cities use the same station and get the same climate inputs. The closest to Lynwood: Compton (3 mi away, 6.4 mi from the station), Gardena (6 mi away, 2.5 mi from the station), Hawthorne (8 mi away, 1.1 mi from the station), Inglewood (8 mi away, 2.3 mi from the station), Lawndale (9 mi away, 2.7 mi from the station). Lynwood is farther from the station than 5 of them.

The sun over Lynwood in late July

At 33.92°N, the noon sun on 21 July stands 76.5° above the horizon over Lynwood and the day runs 13 h 56 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

63,596 people live in Lynwood, the 140th largest of the 376 California cities sized on this site. Coordinates used: 33.9240, -118.2017.

Lynwood AC sizing questions

What size AC does a 2,000 sq ft house in Lynwood, CA need?

About 2 tons, for a cooling load of 24,000 BTU/hr on a 83°F design day. That is one ton per 1,000 square feet in Lynwood's climate.

Is 20 BTU per square foot right for Lynwood?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Hawthorne Municipal Airport. For a single room here, plan on 12 BTU/hr per square foot.

What does central AC cost to run in Lynwood?

About $419 a year: 1,286 kWh at SEER2 14.3 and 32.58¢ per kWh, over 5 cooling months.