ACSizeCheck

What size AC for Livingston, CA? 3.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Livingston needs

3.5 tons central AC or heat pump, about 38,900 BTU/hr of load

Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.2 tons. This is one of the climates the chart was written for.

If a contractor quotes you more than 3.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 617 square feet in this climate. For a single room, size by the room: 19.4 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Merced Municipal Airport (13.4 mi away). Jul is the hottest month, averaging a high of 96.3°F and a low of 61.7°F, with about 100 days a year at 90°F or more. That gives a design temperature of 104°F against 75°F inside.

What it costs to run

About 2,066 kWh a year at SEER2 14.3, or roughly $673 at California's average residential rate of 32.58¢ per kWh. Cooling runs 6 months of the year here.

What drives the load in Livingston

Of the 38,900 BTU/hr, 20,880 comes through walls, roof and windows on a 104°F afternoon (54%), 13,000 is sun on the house (33%), 2,120 is four people and their appliances, and 2,900 is moisture the coil has to wring out of Livingston's summer air (7%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,000 BTU/hr before the moisture allowance.

Other house sizes in Livingston

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft20,6002 tons2 tons
1,500 sq ft29,7002.5 tons2.5 tons
2,500 sq ft48,0004 tons5 tons
3,000 sq ft57,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,900 BTU/hr; a 350 sq ft living room needs about 6,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 11,600 BTU/hr.

Month by month in Livingston

MonthAvg highCooling degree daysAC kWh
Jan55.6°F00
Feb62°F00
Mar68.1°F11
Apr74°F2229
May82.7°F122159
Jun90.7°F279364
Jul96.3°F434566
Aug95.1°F399520
Sep90.5°F262341
Oct79.6°F6483
Nov66.1°F12
Dec56°F00

Jul alone uses 27% of the year's cooling energy. The unit runs the equivalent of 760 hours a year at full output.

Livingston against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Atwater, CA7 mi104°F3.5 tons
Turlock, CA11 mi102°F3.5 tons
Merced, CA15 mi104°F3.5 tons
Newman, CA17 mi103°F3.5 tons
Ceres, CA20 mi102°F3.5 tons
Modesto, CA23 mi102°F3.5 tons

Of 376 California cities here, Livingston has the 83rd highest cooling load. The range runs from Corte Madera at 15,700 BTU/hr to Palm Desert at 59,000.

Where Livingston's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Merced Municipal Airport, 13.4 miles from the center of Livingston at 152 ft above sea level. That is close enough that the station's summers are Livingston's summers.

2 other cities use the same station and get the same climate inputs. The closest to Livingston: Atwater (7 mi away, 6.4 mi from the station), Merced (15 mi away, 3.1 mi from the station). Livingston is farther from the station than 2 of them.

The sun over Livingston in late July

At 37.39°N, the noon sun on 21 July stands 73.0° above the horizon over Livingston and the day runs 14 h 12 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

14,767 people live in Livingston, the 327th largest of the 376 California cities sized on this site. Coordinates used: 37.3873, -120.7249.

Livingston AC sizing questions

What size AC does a 2,000 sq ft house in Livingston, CA need?

About 3.5 tons, for a cooling load of 38,900 BTU/hr on a 104°F design day. That is one ton per 617 square feet in Livingston's climate.

Is 20 BTU per square foot right for Livingston?

The chart gives 3.5 tons for 2,000 sq ft, against 3.5 tons sized from NOAA's 1991 to 2020 normals at Merced Municipal Airport. For a single room here, plan on 19.4 BTU/hr per square foot.

What does central AC cost to run in Livingston?

About $673 a year: 2,066 kWh at SEER2 14.3 and 32.58¢ per kWh, over 6 cooling months.