ACSizeCheck

What size AC for Lewisville, NC? 3 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lewisville needs

3 tons central AC or heat pump, about 34,300 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 23% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 701 square feet in this climate. For a single room, size by the room: 17.1 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Winston Salem Reynolds Airport (11.3 mi away). Jul is the hottest month, averaging a high of 88°F and a low of 69.2°F, with about 33 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.

What it costs to run

About 2,231 kWh a year at SEER2 14.3, or roughly $333 at North Carolina's average residential rate of 14.94¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Lewisville

Of the 34,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (38%), 13,000 is sun on the house (38%), 2,120 is four people and their appliances, and 6,200 is moisture the coil has to wring out of Lewisville's summer air (18%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.

Other house sizes in Lewisville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft18,4001.5 tons2 tons
1,500 sq ft26,3002.5 tons2.5 tons
2,500 sq ft42,2004 tons5 tons
3,000 sq ft50,1004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,300 BTU/hr.

Month by month in Lewisville

MonthAvg highCooling degree daysAC kWh
Jan48.8°F00
Feb52.8°F11
Mar60.8°F710
Apr70.6°F3957
May77.9°F134198
Jun84.9°F308454
Jul88°F422622
Aug86.1°F373549
Sep80.1°F193284
Oct70.6°F3552
Nov60.1°F23
Dec51.7°F11

Jul alone uses 28% of the year's cooling energy. The unit runs the equivalent of 931 hours a year at full output.

Lewisville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Clemmons, NC5 mi93°F3 tons
Winston-Salem, NC9 mi93°F3 tons
Kernersville, NC19 mi94°F3 tons
Lexington, NC23 mi94°F3 tons
Thomasville, NC25 mi94°F3 tons
High Point, NC25 mi94°F3 tons

Of 91 North Carolina cities here, Lewisville has the 77th highest cooling load. The range runs from Boone at 21,700 BTU/hr to Lumberton at 40,200.

Where Lewisville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Winston Salem Reynolds Airport, 11.3 miles from the center of Lewisville at 957 ft above sea level. That is close enough that the station's summers are Lewisville's summers.

2 other cities use the same station and get the same climate inputs. The closest to Lewisville: Clemmons (5 mi away, 11.4 mi from the station), Winston-Salem (9 mi away, 2.9 mi from the station). Lewisville is farther from the station than 1 of them.

The sun over Lewisville in late July

At 36.11°N, the noon sun on 21 July stands 74.3° above the horizon over Lewisville and the day runs 14 h 06 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

14,203 people live in Lewisville, the 76th largest of the 91 North Carolina cities sized on this site. Coordinates used: 36.1052, -80.4246.

Lewisville AC sizing questions

What size AC does a 2,000 sq ft house in Lewisville, NC need?

About 3 tons, for a cooling load of 34,300 BTU/hr on a 93°F design day. That is one ton per 701 square feet in Lewisville's climate.

Is 20 BTU per square foot right for Lewisville?

The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Winston Salem Reynolds Airport. For a single room here, plan on 17.1 BTU/hr per square foot.

What does central AC cost to run in Lewisville?

About $333 a year: 2,231 kWh at SEER2 14.3 and 14.94¢ per kWh, over 5 cooling months.