ACSizeCheck

What size AC for Lemont, IL? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lemont needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago Midway Airport (14.3 mi away). Jul is the hottest month, averaging a high of 85°F and a low of 67.7°F, with about 20 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,544 kWh a year at SEER2 14.3, or roughly $297 at Illinois's average residential rate of 19.23¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Lemont

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Lemont's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Lemont

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Lemont

MonthAvg highCooling degree daysAC kWh
Jan32.7°F00
Feb36.8°F00
Mar47.6°F23
Apr59.9°F912
May71.1°F7199
Jun80.9°F222308
Jul85°F353490
Aug82.7°F299415
Sep76.3°F136188
Oct63.4°F2028
Nov49.1°F01
Dec37.6°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 741 hours a year at full output.

Lemont against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Homer Glen, IL5 mi90°F2.5 tons
Darien, IL5 mi90°F2.5 tons
Woodridge, IL6 mi90°F2.5 tons
Lockport, IL6 mi89°F2.5 tons
Bolingbrook, IL6 mi88°F2.5 tons
Burr Ridge, IL6 mi90°F2.5 tons

Of 225 Illinois cities here, Lemont has the 71st highest cooling load. The range runs from Fox Lake at 24,900 BTU/hr to Granite City at 36,000.

Where Lemont's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago Midway Airport, 14.3 miles from the center of Lemont at 610 ft above sea level. That is close enough that the station's summers are Lemont's summers.

51 other cities use the same station and get the same climate inputs. The closest to Lemont: Homer Glen (5 mi away, 16 mi from the station), Darien (5 mi away, 12 mi from the station), Woodridge (6 mi away, 15.2 mi from the station), Burr Ridge (6 mi away, 8.9 mi from the station), Orland Park (8 mi away, 13.3 mi from the station). Lemont is farther from the station than 35 of them.

The sun over Lemont in late July

At 41.67°N, the noon sun on 21 July stands 68.7° above the horizon over Lemont and the day runs 14 h 35 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

18,203 people live in Lemont, the 138th largest of the 225 Illinois cities sized on this site. Coordinates used: 41.6673, -87.9844.

Lemont AC sizing questions

What size AC does a 2,000 sq ft house in Lemont, IL need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Lemont's climate.

Is 20 BTU per square foot right for Lemont?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Midway Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Lemont?

About $297 a year: 1,544 kWh at SEER2 14.3 and 19.23¢ per kWh, over 5 cooling months.