What size AC for Lawton, OK? 4 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Lawton needs
4 tons central AC or heat pump, about 44,800 BTU/hr of load
Here the 20 BTU per square foot chart lands close: 3.5 tons against a load of 3.7 tons. This is one of the climates the chart was written for.
If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 536 square feet in this climate. For a single room, size by the room: 22.4 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Lawton Municipal Airport (4.1 mi away). Jul is the hottest month, averaging a high of 97.2°F and a low of 71.5°F, with about 102 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.
What it costs to run
About 3,422 kWh a year at SEER2 14.3, or roughly $473 at Oklahoma's average residential rate of 13.81¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Lawton
Of the 44,800 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (48%), 13,000 is sun on the house (29%), 2,120 is four people and their appliances, and 8,100 is moisture the coil has to wring out of Lawton's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.
Other house sizes in Lawton
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 23,700 | 2 tons | 2 tons |
| 1,500 sq ft | 34,200 | 3 tons | 2.5 tons |
| 2,500 sq ft | 55,400 | 5 tons | 5 tons |
| 3,000 sq ft | 65,900 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,400 BTU/hr; a 350 sq ft living room needs about 7,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 13,400 BTU/hr.
Month by month in Lawton
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 53.7°F | 0 | 0 |
| Feb | 58°F | 2 | 2 |
| Mar | 66.8°F | 16 | 23 |
| Apr | 74.8°F | 56 | 83 |
| May | 83.2°F | 216 | 318 |
| Jun | 92°F | 451 | 665 |
| Jul | 97.2°F | 600 | 884 |
| Aug | 96.4°F | 575 | 847 |
| Sep | 87.6°F | 314 | 463 |
| Oct | 76.5°F | 85 | 126 |
| Nov | 64.1°F | 6 | 9 |
| Dec | 54.3°F | 0 | 0 |
Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,092 hours a year at full output.
Lawton against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Duncan, OK | 28 mi | 100°F | 3.5 tons |
| Burkburnett, TX | 38 mi | 105°F | 4 tons |
| Chickasha, OK | 40 mi | 104°F | 4 tons |
| Wichita Falls, TX | 49 mi | 105°F | 4 tons |
| Altus, OK | 51 mi | 105°F | 4 tons |
| Newcastle, OK | 64 mi | 100°F | 3.5 tons |
Of 45 Oklahoma cities here, Lawton has the 2nd highest cooling load. The range runs from Miami at 35,600 BTU/hr to Ardmore at 44,900.
Where Lawton's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Lawton Municipal Airport, 4.1 miles from the center of Lawton at 1,070 ft above sea level. That is close enough that the station's summers are Lawton's summers.
No other city in this set uses Lawton Municipal Airport, so this sizing is Lawton's alone.
The sun over Lawton in late July
At 34.62°N, the noon sun on 21 July stands 75.8° above the horizon over Lawton and the day runs 13 h 59 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
90,027 people live in Lawton, the 6th largest of the 45 Oklahoma cities sized on this site. Coordinates used: 34.6172, -98.4214.
Lawton AC sizing questions
What size AC does a 2,000 sq ft house in Lawton, OK need?
About 4 tons, for a cooling load of 44,800 BTU/hr on a 105°F design day. That is one ton per 536 square feet in Lawton's climate.
Is 20 BTU per square foot right for Lawton?
The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Lawton Municipal Airport. For a single room here, plan on 22.4 BTU/hr per square foot.
What does central AC cost to run in Lawton?
About $473 a year: 3,422 kWh at SEER2 14.3 and 13.81¢ per kWh, over 7 cooling months.