What size AC for Laurel, MD? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Laurel needs
3 tons central AC or heat pump, about 33,100 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 27% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 725 square feet in this climate. For a single room, size by the room: 16.6 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Baltimore-Washington International Airport (10.9 mi away). Jul is the hottest month, averaging a high of 88.8°F and a low of 67.7°F, with about 34 days a year at 90°F or more. That gives a design temperature of 94°F against 75°F inside.
What it costs to run
About 1,837 kWh a year at SEER2 14.3, or roughly $391 at Maryland's average residential rate of 21.31¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Laurel
Of the 33,100 BTU/hr, 13,680 comes through walls, roof and windows on a 94°F afternoon (41%), 13,000 is sun on the house (39%), 2,120 is four people and their appliances, and 4,300 is moisture the coil has to wring out of Laurel's summer air (13%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 28,800 BTU/hr before the moisture allowance.
Other house sizes in Laurel
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 17,800 | 1.5 tons | 2 tons |
| 1,500 sq ft | 25,400 | 2 tons | 2.5 tons |
| 2,500 sq ft | 40,800 | 3.5 tons | 5 tons |
| 3,000 sq ft | 48,500 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,500 BTU/hr; a 350 sq ft living room needs about 5,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,000 BTU/hr.
Month by month in Laurel
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 43.2°F | 0 | 0 |
| Feb | 46.4°F | 0 | 0 |
| Mar | 54.8°F | 2 | 3 |
| Apr | 66.5°F | 19 | 26 |
| May | 75.5°F | 90 | 125 |
| Jun | 84.4°F | 266 | 370 |
| Jul | 88.8°F | 411 | 571 |
| Aug | 86.5°F | 346 | 481 |
| Sep | 79.7°F | 163 | 227 |
| Oct | 68.3°F | 24 | 33 |
| Nov | 57.3°F | 1 | 1 |
| Dec | 47.5°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 793 hours a year at full output.
Laurel against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Greenbelt, MD | 7 mi | 95°F | 3.5 tons |
| College Park, MD | 8 mi | 95°F | 3.5 tons |
| New Carrollton, MD | 9 mi | 95°F | 3.5 tons |
| Hyattsville, MD | 11 mi | 95°F | 3.5 tons |
| Takoma Park, MD | 11 mi | 95°F | 3.5 tons |
| Bowie, MD | 12 mi | 91°F | 3 tons |
Of 23 Maryland cities here, Laurel has the 15th highest cooling load. The range runs from Westminster at 28,000 BTU/hr to Baltimore at 39,300.
Where Laurel's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Baltimore-Washington International Airport, 10.9 miles from the center of Laurel at 138 ft above sea level. That is close enough that the station's summers are Laurel's summers.
No other city in this set uses Baltimore-Washington International Airport, so this sizing is Laurel's alone.
The sun over Laurel in late July
At 39.10°N, the noon sun on 21 July stands 71.3° above the horizon over Laurel and the day runs 14 h 21 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
30,238 people live in Laurel, the 10th largest of the 23 Maryland cities sized on this site. Coordinates used: 39.0951, -76.8612.
Laurel AC sizing questions
What size AC does a 2,000 sq ft house in Laurel, MD need?
About 3 tons, for a cooling load of 33,100 BTU/hr on a 94°F design day. That is one ton per 725 square feet in Laurel's climate.
Is 20 BTU per square foot right for Laurel?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Baltimore-Washington International Airport. For a single room here, plan on 16.6 BTU/hr per square foot.
What does central AC cost to run in Laurel?
About $391 a year: 1,837 kWh at SEER2 14.3 and 21.31¢ per kWh, over 5 cooling months.