ACSizeCheck

What size AC for Lansdale, PA? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lansdale needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Willow Grove NAS (7.5 mi away). Jul is the hottest month, averaging a high of 85.2°F and a low of 66.7°F, with about 22 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,427 kWh a year at SEER2 14.3, or roughly $301 at Pennsylvania's average residential rate of 21.13¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Lansdale

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Lansdale's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Lansdale

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Lansdale

MonthAvg highCooling degree daysAC kWh
Jan39.7°F00
Feb42.9°F00
Mar51.1°F01
Apr62.7°F1419
May72.4°F6286
Jun80.9°F204283
Jul85.2°F340472
Aug82.9°F279387
Sep76.1°F114159
Oct64.4°F1419
Nov53.9°F01
Dec43.6°F00

Jul alone uses 33% of the year's cooling energy. The unit runs the equivalent of 684 hours a year at full output.

Lansdale against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Norristown, PA9 mi90°F2.5 tons
Phoenixville, PA15 mi88°F2.5 tons
Philadelphia, PA18 mi93°F3 tons
Pottstown, PA19 mi88°F2.5 tons
Lansdowne, PA21 mi93°F3 tons
Yeadon, PA21 mi93°F3 tons

Of 68 Pennsylvania cities here, Lansdale has the 24th highest cooling load. The range runs from St. Marys at 21,700 BTU/hr to Philadelphia at 34,300.

Where Lansdale's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Willow Grove NAS, 7.5 miles from the center of Lansdale at 361 ft above sea level. That is close enough that the station's summers are Lansdale's summers.

1 other city uses the same station and get the same climate inputs. The closest to Lansdale: Norristown (9 mi away, 11.4 mi from the station). Lansdale sits closer to the station than any of them, so its numbers are the best measured of the group.

The sun over Lansdale in late July

At 40.24°N, the noon sun on 21 July stands 70.2° above the horizon over Lansdale and the day runs 14 h 27 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

19,154 people live in Lansdale, the 31st largest of the 68 Pennsylvania cities sized on this site. Coordinates used: 40.2417, -75.2812.

Lansdale AC sizing questions

What size AC does a 2,000 sq ft house in Lansdale, PA need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Lansdale's climate.

Is 20 BTU per square foot right for Lansdale?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Willow Grove NAS. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Lansdale?

About $301 a year: 1,427 kWh at SEER2 14.3 and 21.13¢ per kWh, over 5 cooling months.