ACSizeCheck

What size AC for Lakeway, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Lakeway needs

4 tons central AC or heat pump, about 48,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 493 square feet in this climate. For a single room, size by the room: 24.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Austin-Camp Mabry (13.7 mi away). Aug is the hottest month, averaging a high of 97.8°F and a low of 75.1°F, with about 123 days a year at 90°F or more. That gives a design temperature of 106°F against 75°F inside.

What it costs to run

About 5,168 kWh a year at SEER2 14.3, or roughly $828 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 9 months of the year here.

What drives the load in Lakeway

Of the 48,700 BTU/hr, 22,320 comes through walls, roof and windows on a 106°F afternoon (46%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,200 is moisture the coil has to wring out of Lakeway's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 37,440 BTU/hr before the moisture allowance.

Other house sizes in Lakeway

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft25,7002 tons2 tons
1,500 sq ft37,2003.5 tons2.5 tons
2,500 sq ft60,2005 tons5 tons
3,000 sq ft71,6005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,600 BTU/hr.

Month by month in Lakeway

MonthAvg highCooling degree daysAC kWh
Jan62.5°F1015
Feb66.5°F2438
Mar73.3°F73115
Apr80.3°F172270
May86.9°F370581
Jun93.2°F541850
Jul96.6°F6451,013
Aug97.8°F6651,044
Sep91.4°F474744
Oct82.5°F238374
Nov71.5°F6298
Dec63.9°F1625

Aug alone uses 20% of the year's cooling energy. The unit runs the equivalent of 1,518 hours a year at full output.

Lakeway against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Lago Vista, TX7 mi103°F4 tons
Dripping Springs, TX13 mi103°F4 tons
Austin, TX14 mi106°F4 tons
Cedar Park, TX15 mi106°F4 tons
Leander, TX17 mi103°F4 tons
Buda, TX21 mi105°F4 tons

Of 252 Texas cities here, Lakeway has the 27th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Lakeway's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Austin-Camp Mabry, 13.7 miles from the center of Lakeway at 670 ft above sea level. That is close enough that the station's summers are Lakeway's summers.

6 other cities use the same station and get the same climate inputs. The closest to Lakeway: Austin (14 mi away, 1.6 mi from the station), Cedar Park (15 mi away, 13.5 mi from the station), Round Rock (23 mi away, 15.3 mi from the station), Pflugerville (24 mi away, 12.9 mi from the station), Manor (26 mi away, 12.3 mi from the station). Lakeway is farther from the station than 4 of them.

The sun over Lakeway in late July

At 30.36°N, the noon sun on 21 July stands 80.0° above the horizon over Lakeway and the day runs 13 h 41 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

19,056 people live in Lakeway, the 162nd largest of the 252 Texas cities sized on this site. Coordinates used: 30.3550, -97.9863.

Lakeway AC sizing questions

What size AC does a 2,000 sq ft house in Lakeway, TX need?

About 4 tons, for a cooling load of 48,700 BTU/hr on a 106°F design day. That is one ton per 493 square feet in Lakeway's climate.

Is 20 BTU per square foot right for Lakeway?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Austin-Camp Mabry. For a single room here, plan on 24.3 BTU/hr per square foot.

What does central AC cost to run in Lakeway?

About $828 a year: 5,168 kWh at SEER2 14.3 and 16.03¢ per kWh, over 9 cooling months.