ACSizeCheck

What size AC for Kendallville, IN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Kendallville needs

2.5 tons central AC or heat pump, about 26,400 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 59% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 908 square feet in this climate. For a single room, size by the room: 13.2 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Garrett (9.7 mi away). Jul is the hottest month, averaging a high of 84°F and a low of 62.1°F, with about 15 days a year at 90°F or more. That gives a design temperature of 88°F against 75°F inside.

What it costs to run

About 970 kWh a year at SEER2 14.3, or roughly $165 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Kendallville

Of the 26,400 BTU/hr, 9,360 comes through walls, roof and windows on a 88°F afternoon (35%), 13,000 is sun on the house (49%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Kendallville's summer air (8%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 24,480 BTU/hr before the moisture allowance.

Other house sizes in Kendallville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,4001.5 tons2 tons
1,500 sq ft20,4002 tons2.5 tons
2,500 sq ft32,5003 tons5 tons
3,000 sq ft38,5003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,600 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,900 BTU/hr.

Month by month in Kendallville

MonthAvg highCooling degree daysAC kWh
Jan31.7°F00
Feb35.4°F00
Mar46.2°F11
Apr59.6°F56
May70.7°F4357
Jun80.1°F158207
Jul84°F255333
Aug81.6°F193251
Sep75.7°F79102
Oct62.8°F1013
Nov48.3°F00
Dec36.6°F00

Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 525 hours a year at full output.

Kendallville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Auburn, IN12 mi85°F2 tons
Huntertown, IN16 mi89°F2.5 tons
Columbia City, IN22 mi87°F2 tons
Fort Wayne, IN25 mi89°F2.5 tons
Sturgis, MI26 mi87°F2 tons
New Haven, IN29 mi89°F2.5 tons

Of 88 Indiana cities here, Kendallville has the 80th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Kendallville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Garrett, 9.7 miles from the center of Kendallville at 880 ft above sea level. That is close enough that the station's summers are Kendallville's summers.

No other city in this set uses Garrett, so this sizing is Kendallville's alone.

The sun over Kendallville in late July

At 41.44°N, the noon sun on 21 July stands 69.0° above the horizon over Kendallville and the day runs 14 h 33 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

10,326 people live in Kendallville, the 83rd largest of the 88 Indiana cities sized on this site. Coordinates used: 41.4434, -85.2582.

Kendallville AC sizing questions

What size AC does a 2,000 sq ft house in Kendallville, IN need?

About 2.5 tons, for a cooling load of 26,400 BTU/hr on a 88°F design day. That is one ton per 908 square feet in Kendallville's climate.

Is 20 BTU per square foot right for Kendallville?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Garrett. For a single room here, plan on 13.2 BTU/hr per square foot.

What does central AC cost to run in Kendallville?

About $165 a year: 970 kWh at SEER2 14.3 and 17.04¢ per kWh, over 4 cooling months.