What size AC for Jersey City, NJ? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Jersey City needs
3 tons central AC or heat pump, about 33,400 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 26% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 719 square feet in this climate. For a single room, size by the room: 16.7 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Newark Liberty International Airport (5.8 mi away). Jul is the hottest month, averaging a high of 86.9°F and a low of 69.4°F, with about 28 days a year at 90°F or more. That gives a design temperature of 92°F against 75°F inside.
What it costs to run
About 1,872 kWh a year at SEER2 14.3, or roughly $451 at New Jersey's average residential rate of 24.09¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Jersey City
Of the 33,400 BTU/hr, 12,240 comes through walls, roof and windows on a 92°F afternoon (37%), 13,000 is sun on the house (39%), 2,120 is four people and their appliances, and 6,000 is moisture the coil has to wring out of Jersey City's summer air (18%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 27,360 BTU/hr before the moisture allowance.
Other house sizes in Jersey City
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 18,000 | 1.5 tons | 2 tons |
| 1,500 sq ft | 25,700 | 2 tons | 2.5 tons |
| 2,500 sq ft | 41,100 | 3.5 tons | 5 tons |
| 3,000 sq ft | 48,800 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,500 BTU/hr; a 350 sq ft living room needs about 5,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,000 BTU/hr.
Month by month in Jersey City
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 40°F | 0 | 0 |
| Feb | 43°F | 0 | 0 |
| Mar | 50.9°F | 1 | 1 |
| Apr | 62.6°F | 14 | 20 |
| May | 72.6°F | 69 | 102 |
| Jun | 81.8°F | 245 | 361 |
| Jul | 86.9°F | 408 | 601 |
| Aug | 84.7°F | 353 | 520 |
| Sep | 77.7°F | 159 | 235 |
| Oct | 66°F | 21 | 31 |
| Nov | 54.9°F | 1 | 1 |
| Dec | 44.8°F | 0 | 0 |
Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 802 hours a year at full output.
Jersey City against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Hoboken, NJ | 3 mi | 89°F | 2.5 tons |
| Bayonne, NJ | 4 mi | 92°F | 3 tons |
| Kearny, NJ | 4 mi | 92°F | 3 tons |
| Union City, NJ | 4 mi | 89°F | 2.5 tons |
| Secaucus, NJ | 5 mi | 89°F | 2.5 tons |
| Harrison, NJ | 5 mi | 92°F | 3 tons |
Of 116 New Jersey cities here, Jersey City has the 10th highest cooling load. The range runs from Hackettstown at 26,400 BTU/hr to Camden at 34,300.
Where Jersey City's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Newark Liberty International Airport, 5.8 miles from the center of Jersey City at 6 ft above sea level. That is close enough that the station's summers are Jersey City's summers.
18 other cities use the same station and get the same climate inputs. The closest to Jersey City: Bayonne (4 mi away, 3.4 mi from the station), Kearny (4 mi away, 5.4 mi from the station), Harrison (5 mi away, 4.2 mi from the station), Newark (6 mi away, 2.9 mi from the station), Elizabeth (7 mi away, 1.7 mi from the station). Jersey City is farther from the station than 8 of them.
The sun over Jersey City in late July
At 40.71°N, the noon sun on 21 July stands 69.7° above the horizon over Jersey City and the day runs 14 h 29 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
302,824 people live in Jersey City, the 2nd largest of the 116 New Jersey cities sized on this site. Coordinates used: 40.7114, -74.0648.
Jersey City AC sizing questions
What size AC does a 2,000 sq ft house in Jersey City, NJ need?
About 3 tons, for a cooling load of 33,400 BTU/hr on a 92°F design day. That is one ton per 719 square feet in Jersey City's climate.
Is 20 BTU per square foot right for Jersey City?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Newark Liberty International Airport. For a single room here, plan on 16.7 BTU/hr per square foot.
What does central AC cost to run in Jersey City?
About $451 a year: 1,872 kWh at SEER2 14.3 and 24.09¢ per kWh, over 5 cooling months.