ACSizeCheck

What size AC for Highland, IN? 2.5 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Highland needs

2.5 tons central AC or heat pump, about 29,800 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 41% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 805 square feet in this climate. For a single room, size by the room: 14.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Chicago Midway Airport (22.5 mi away). Jul is the hottest month, averaging a high of 85°F and a low of 67.7°F, with about 20 days a year at 90°F or more. That gives a design temperature of 90°F against 75°F inside.

What it costs to run

About 1,544 kWh a year at SEER2 14.3, or roughly $263 at Indiana's average residential rate of 17.04¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Highland

Of the 29,800 BTU/hr, 10,800 comes through walls, roof and windows on a 90°F afternoon (36%), 13,000 is sun on the house (44%), 2,120 is four people and their appliances, and 3,900 is moisture the coil has to wring out of Highland's summer air (13%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,920 BTU/hr before the moisture allowance.

Other house sizes in Highland

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft16,1001.5 tons2 tons
1,500 sq ft23,0002 tons2.5 tons
2,500 sq ft36,7003.5 tons5 tons
3,000 sq ft43,5004 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,200 BTU/hr; a 350 sq ft living room needs about 5,200 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,900 BTU/hr.

Month by month in Highland

MonthAvg highCooling degree daysAC kWh
Jan32.7°F00
Feb36.8°F00
Mar47.6°F23
Apr59.9°F912
May71.1°F7199
Jun80.9°F222308
Jul85°F353490
Aug82.7°F299415
Sep76.3°F136188
Oct63.4°F2028
Nov49.1°F01
Dec37.6°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 741 hours a year at full output.

Highland against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Griffith, IN2 mi90°F2.5 tons
Munster, IN2 mi90°F2.5 tons
Dyer, IN4 mi90°F2.5 tons
Schererville, IN4 mi90°F2.5 tons
Lansing, IL5 mi90°F2.5 tons
Hammond, IN5 mi90°F2.5 tons

Of 88 Indiana cities here, Highland has the 39th highest cooling load. The range runs from Auburn at 24,100 BTU/hr to Jasper at 36,400.

Where Highland's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Chicago Midway Airport, across the line in Illinois, 22.5 miles from the center of Highland at 610 ft above sea level. That is close enough that the station's summers are Highland's summers.

51 other cities use the same station and get the same climate inputs. The closest to Highland: Munster (2 mi away, 20.9 mi from the station), Dyer (4 mi away, 23.5 mi from the station), Lansing (5 mi away, 18.6 mi from the station), Hammond (5 mi away, 17.6 mi from the station), Calumet City (5 mi away, 17.1 mi from the station). Highland is farther from the station than 50 of them.

The sun over Highland in late July

At 41.55°N, the noon sun on 21 July stands 68.9° above the horizon over Highland and the day runs 14 h 34 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

23,497 people live in Highland, the 44th largest of the 88 Indiana cities sized on this site. Coordinates used: 41.5466, -87.4576.

Highland AC sizing questions

What size AC does a 2,000 sq ft house in Highland, IN need?

About 2.5 tons, for a cooling load of 29,800 BTU/hr on a 90°F design day. That is one ton per 805 square feet in Highland's climate.

Is 20 BTU per square foot right for Highland?

The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Chicago Midway Airport. For a single room here, plan on 14.9 BTU/hr per square foot.

What does central AC cost to run in Highland?

About $263 a year: 1,544 kWh at SEER2 14.3 and 17.04¢ per kWh, over 5 cooling months.