ACSizeCheck

What size AC for Hidalgo, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Hidalgo needs

4 tons central AC or heat pump, about 50,500 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 475 square feet in this climate. For a single room, size by the room: 25.3 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Mcallen Miller International Airport (4.9 mi away). Aug is the hottest month, averaging a high of 99.6°F and a low of 78.9°F, with about 177 days a year at 90°F or more. That gives a design temperature of 108°F against 75°F inside.

What it costs to run

About 7,837 kWh a year at SEER2 14.3, or roughly $1,256 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 12 months of the year here.

What drives the load in Hidalgo

Of the 50,500 BTU/hr, 23,760 comes through walls, roof and windows on a 108°F afternoon (47%), 13,000 is sun on the house (26%), 2,120 is four people and their appliances, and 11,700 is moisture the coil has to wring out of Hidalgo's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 38,880 BTU/hr before the moisture allowance.

Other house sizes in Hidalgo

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft26,7002.5 tons2 tons
1,500 sq ft38,6003.5 tons2.5 tons
2,500 sq ft62,5005 tons5 tons
3,000 sq ft74,4005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,800 BTU/hr; a 350 sq ft living room needs about 8,900 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 15,200 BTU/hr.

Month by month in Hidalgo

MonthAvg highCooling degree daysAC kWh
Jan72.8°F81127
Feb77.4°F139218
Mar83.2°F274431
Apr88.4°F407639
May93.1°F577906
Jun97.4°F6811,069
Jul98.5°F7331,152
Aug99.6°F7521,181
Sep94.3°F599940
Oct89.3°F438688
Nov80.2°F206324
Dec73.8°F104163

Aug alone uses 15% of the year's cooling energy. The unit runs the equivalent of 2,217 hours a year at full output.

Hidalgo against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Pharr, TX5 mi108°F4 tons
McAllen, TX8 mi108°F4 tons
San Juan, TX8 mi108°F4 tons
Mission, TX8 mi108°F4 tons
Alamo, TX9 mi108°F4 tons
Palmview, TX12 mi108°F4 tons

Of 252 Texas cities here, Hidalgo has the 13th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Hidalgo's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Mcallen Miller International Airport, 4.9 miles from the center of Hidalgo at 99 ft above sea level. That is close enough that the station's summers are Hidalgo's summers.

10 other cities use the same station and get the same climate inputs. The closest to Hidalgo: Pharr (5 mi away, 3.3 mi from the station), McAllen (8 mi away, 3.2 mi from the station), San Juan (8 mi away, 5.8 mi from the station), Mission (8 mi away, 5.3 mi from the station), Alamo (9 mi away, 7.9 mi from the station). Hidalgo is farther from the station than 2 of them.

The sun over Hidalgo in late July

At 26.11°N, the noon sun on 21 July stands 84.3° above the horizon over Hidalgo and the day runs 13 h 24 min from sunrise to sunset. With the sun that close to overhead, the roof takes most of the heat at midday and the west wall takes the rest after 3 pm. Shorter days give the house a longer night to shed the day's heat.

15,164 people live in Hidalgo, the 193rd largest of the 252 Texas cities sized on this site. Coordinates used: 26.1089, -98.2462.

Hidalgo AC sizing questions

What size AC does a 2,000 sq ft house in Hidalgo, TX need?

About 4 tons, for a cooling load of 50,500 BTU/hr on a 108°F design day. That is one ton per 475 square feet in Hidalgo's climate.

Is 20 BTU per square foot right for Hidalgo?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Mcallen Miller International Airport. For a single room here, plan on 25.3 BTU/hr per square foot.

What does central AC cost to run in Hidalgo?

About $1,256 a year: 7,837 kWh at SEER2 14.3 and 16.03¢ per kWh, over 12 cooling months.