ACSizeCheck

What size AC for Hewitt, TX? 4 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Hewitt needs

4 tons central AC or heat pump, about 47,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, which falls short here. On a design day the unit runs flat out and the house still drifts above 75°F by late afternoon.

If a contractor quotes you more than 4 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 503 square feet in this climate. For a single room, size by the room: 23.9 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Waco Regional Airport (11.7 mi away). Aug is the hottest month, averaging a high of 97.1°F and a low of 73.9°F, with about 115 days a year at 90°F or more. That gives a design temperature of 105°F against 75°F inside.

What it costs to run

About 4,505 kWh a year at SEER2 14.3, or roughly $722 at Texas's average residential rate of 16.03¢ per kWh. Cooling runs 7 months of the year here.

What drives the load in Hewitt

Of the 47,700 BTU/hr, 21,600 comes through walls, roof and windows on a 105°F afternoon (45%), 13,000 is sun on the house (27%), 2,120 is four people and their appliances, and 11,000 is moisture the coil has to wring out of Hewitt's summer air (23%).

Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 36,720 BTU/hr before the moisture allowance.

Other house sizes in Hewitt

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft25,2002 tons2 tons
1,500 sq ft36,5003 tons2.5 tons
2,500 sq ft59,0005 tons5 tons
3,000 sq ft70,2005 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 3,600 BTU/hr; a 350 sq ft living room needs about 8,400 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 14,300 BTU/hr.

Month by month in Hewitt

MonthAvg highCooling degree daysAC kWh
Jan59.1°F35
Feb63.1°F1015
Mar70.2°F3859
Apr77.9°F114179
May85.3°F297466
Jun92.7°F507796
Jul96.7°F6371,001
Aug97.1°F635998
Sep90.8°F416653
Oct80.7°F171268
Nov68.8°F3454
Dec60.4°F711

Jul alone uses 22% of the year's cooling energy. The unit runs the equivalent of 1,349 hours a year at full output.

Hewitt against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Robinson, TX4 mi105°F4 tons
Waco, TX7 mi105°F4 tons
Bellmead, TX12 mi105°F4 tons
Temple, TX27 mi104°F4 tons
Belton, TX32 mi104°F4 tons
Gatesville, TX33 mi104°F4 tons

Of 252 Texas cities here, Hewitt has the 58th highest cooling load. The range runs from Levelland at 37,300 BTU/hr to Laredo at 51,500.

Where Hewitt's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Waco Regional Airport, 11.7 miles from the center of Hewitt at 498 ft above sea level. That is close enough that the station's summers are Hewitt's summers.

3 other cities use the same station and get the same climate inputs. The closest to Hewitt: Robinson (4 mi away, 13.1 mi from the station), Waco (7 mi away, 4.7 mi from the station), Bellmead (12 mi away, 8.3 mi from the station). Hewitt is farther from the station than 2 of them.

The sun over Hewitt in late July

At 31.45°N, the noon sun on 21 July stands 78.9° above the horizon over Hewitt and the day runs 13 h 45 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

16,749 people live in Hewitt, the 179th largest of the 252 Texas cities sized on this site. Coordinates used: 31.4512, -97.1933.

Hewitt AC sizing questions

What size AC does a 2,000 sq ft house in Hewitt, TX need?

About 4 tons, for a cooling load of 47,700 BTU/hr on a 105°F design day. That is one ton per 503 square feet in Hewitt's climate.

Is 20 BTU per square foot right for Hewitt?

The chart gives 3.5 tons for 2,000 sq ft, against 4 tons sized from NOAA's 1991 to 2020 normals at Waco Regional Airport. For a single room here, plan on 23.9 BTU/hr per square foot.

What does central AC cost to run in Hewitt?

About $722 a year: 4,505 kWh at SEER2 14.3 and 16.03¢ per kWh, over 7 cooling months.