What size AC for Griffin, GA? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Griffin needs
3 tons central AC or heat pump, about 36,000 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 17% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 666 square feet in this climate. For a single room, size by the room: 18 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Experiment (1.5 mi away). Jul is the hottest month, averaging a high of 89.8°F and a low of 69°F, with about 39 days a year at 90°F or more. That gives a design temperature of 95°F against 75°F inside.
What it costs to run
About 2,661 kWh a year at SEER2 14.3, or roughly $412 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 7 months of the year here.
What drives the load in Griffin
Of the 36,000 BTU/hr, 14,400 comes through walls, roof and windows on a 95°F afternoon (40%), 13,000 is sun on the house (36%), 2,120 is four people and their appliances, and 6,500 is moisture the coil has to wring out of Griffin's summer air (18%).
Heat through the shell is the biggest share here, so insulation and air sealing cut the size you need more than shading would. Sensible heat totals 29,520 BTU/hr before the moisture allowance.
Other house sizes in Griffin
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 19,300 | 1.5 tons | 2 tons |
| 1,500 sq ft | 27,700 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 44,400 | 4 tons | 5 tons |
| 3,000 sq ft | 52,700 | 5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,700 BTU/hr; a 350 sq ft living room needs about 6,300 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,800 BTU/hr.
Month by month in Griffin
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 55.6°F | 0 | 0 |
| Feb | 59°F | 1 | 1 |
| Mar | 66.8°F | 15 | 21 |
| Apr | 74.1°F | 50 | 74 |
| May | 81.2°F | 184 | 271 |
| Jun | 87.3°F | 350 | 516 |
| Jul | 89.8°F | 446 | 658 |
| Aug | 88.5°F | 411 | 605 |
| Sep | 83.9°F | 268 | 395 |
| Oct | 75°F | 68 | 100 |
| Nov | 65.8°F | 11 | 17 |
| Dec | 58°F | 1 | 2 |
Jul alone uses 25% of the year's cooling energy. The unit runs the equivalent of 1,057 hours a year at full output.
Griffin against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Locust Grove, GA | 12 mi | 98°F | 3.5 tons |
| Lovejoy, GA | 14 mi | 96°F | 3.5 tons |
| McDonough, GA | 15 mi | 96°F | 3.5 tons |
| Fayetteville, GA | 18 mi | 97°F | 3.5 tons |
| Stockbridge, GA | 20 mi | 96°F | 3.5 tons |
| Peachtree City, GA | 20 mi | 97°F | 3.5 tons |
Of 101 Georgia cities here, Griffin has the 79th highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.
Where Griffin's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Experiment, 1.5 miles from the center of Griffin at 934 ft above sea level. That is close enough that the station's summers are Griffin's summers.
No other city in this set uses Experiment, so this sizing is Griffin's alone.
The sun over Griffin in late July
At 33.24°N, the noon sun on 21 July stands 77.2° above the horizon over Griffin and the day runs 13 h 53 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
23,994 people live in Griffin, the 49th largest of the 101 Georgia cities sized on this site. Coordinates used: 33.2432, -84.2719.
Griffin AC sizing questions
What size AC does a 2,000 sq ft house in Griffin, GA need?
About 3 tons, for a cooling load of 36,000 BTU/hr on a 95°F design day. That is one ton per 666 square feet in Griffin's climate.
Is 20 BTU per square foot right for Griffin?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Experiment. For a single room here, plan on 18 BTU/hr per square foot.
What does central AC cost to run in Griffin?
About $412 a year: 2,661 kWh at SEER2 14.3 and 15.48¢ per kWh, over 7 cooling months.