What size AC for Greenville, OH? 2.5 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Greenville needs
2.5 tons central AC or heat pump, about 27,200 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 54% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2.5 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 882 square feet in this climate. For a single room, size by the room: 13.6 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Greenville Wtp (1.5 mi away). Jul is the hottest month, averaging a high of 84.6°F and a low of 63.6°F, with about 12 days a year at 90°F or more. That gives a design temperature of 89°F against 75°F inside.
What it costs to run
About 1,217 kWh a year at SEER2 14.3, or roughly $229 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Greenville
Of the 27,200 BTU/hr, 10,080 comes through walls, roof and windows on a 89°F afternoon (37%), 13,000 is sun on the house (48%), 2,120 is four people and their appliances, and 2,000 is moisture the coil has to wring out of Greenville's summer air (7%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 25,200 BTU/hr before the moisture allowance.
Other house sizes in Greenville
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,800 | 1.5 tons | 2 tons |
| 1,500 sq ft | 21,000 | 2 tons | 2.5 tons |
| 2,500 sq ft | 33,400 | 3 tons | 5 tons |
| 3,000 sq ft | 39,700 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,000 BTU/hr; a 350 sq ft living room needs about 4,800 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 8,200 BTU/hr.
Month by month in Greenville
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 35.1°F | 0 | 0 |
| Feb | 39.1°F | 0 | 0 |
| Mar | 49.6°F | 1 | 2 |
| Apr | 62.8°F | 10 | 12 |
| May | 73.2°F | 77 | 100 |
| Jun | 81.6°F | 209 | 272 |
| Jul | 84.6°F | 284 | 371 |
| Aug | 83.3°F | 230 | 300 |
| Sep | 78.1°F | 106 | 138 |
| Oct | 65.6°F | 16 | 21 |
| Nov | 51.6°F | 0 | 1 |
| Dec | 39.8°F | 0 | 0 |
Jul alone uses 30% of the year's cooling energy. The unit runs the equivalent of 639 hours a year at full output.
Greenville against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Piqua, OH | 20 mi | 89°F | 2.5 tons |
| Troy, OH | 22 mi | 90°F | 2.5 tons |
| Clayton, OH | 23 mi | 90°F | 2.5 tons |
| Englewood, OH | 23 mi | 90°F | 2.5 tons |
| Richmond, IN | 24 mi | 89°F | 2.5 tons |
| Tipp City, OH | 25 mi | 90°F | 2.5 tons |
Of 176 Ohio cities here, Greenville has the 116th highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.
Where Greenville's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Greenville Wtp, 1.5 miles from the center of Greenville at 1,030 ft above sea level. That is close enough that the station's summers are Greenville's summers.
No other city in this set uses Greenville Wtp, so this sizing is Greenville's alone.
The sun over Greenville in late July
At 40.10°N, the noon sun on 21 July stands 70.3° above the horizon over Greenville and the day runs 14 h 26 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
12,701 people live in Greenville, the 147th largest of the 176 Ohio cities sized on this site. Coordinates used: 40.1047, -84.6214.
Greenville AC sizing questions
What size AC does a 2,000 sq ft house in Greenville, OH need?
About 2.5 tons, for a cooling load of 27,200 BTU/hr on a 89°F design day. That is one ton per 882 square feet in Greenville's climate.
Is 20 BTU per square foot right for Greenville?
The chart gives 3.5 tons for 2,000 sq ft, against 2.5 tons sized from NOAA's 1991 to 2020 normals at Greenville Wtp. For a single room here, plan on 13.6 BTU/hr per square foot.
What does central AC cost to run in Greenville?
About $229 a year: 1,217 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.