What size AC for Grandville, MI? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Grandville needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Grand Rapids (10.5 mi away). Jul is the hottest month, averaging a high of 83.1°F and a low of 62.5°F, with about 10 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 956 kWh a year at SEER2 14.3, or roughly $208 at Michigan's average residential rate of 21.73¢ per kWh. Cooling runs 4 months of the year here.

What drives the load in Grandville

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Grandville's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Grandville

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Grandville

MonthAvg highCooling degree daysAC kWh
Jan31°F00
Feb33.7°F00
Mar44.5°F12
Apr57.8°F56
May69.8°F4559
Jun79.4°F154200
Jul83.1°F247322
Aug80.9°F200261
Sep73.9°F7396
Oct60.7°F810
Nov47.2°F00
Dec36.1°F00

Jul alone uses 34% of the year's cooling energy. The unit runs the equivalent of 533 hours a year at full output.

Grandville against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Wyoming, MI2 mi87°F2 tons
Grand Rapids, MI6 mi87°F2 tons
Walker, MI7 mi87°F2 tons
East Grand Rapids, MI8 mi87°F2 tons
Kentwood, MI8 mi87°F2 tons
Holland, MI20 mi86°F2 tons

Of 90 Michigan cities here, Grandville has the 61st highest cooling load. The range runs from Marquette at 18,700 BTU/hr to Ypsilanti at 28,800.

Where Grandville's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Grand Rapids, 10.5 miles from the center of Grandville at 875 ft above sea level. That is close enough that the station's summers are Grandville's summers.

5 other cities use the same station and get the same climate inputs. The closest to Grandville: Wyoming (2 mi away, 8.2 mi from the station), Grand Rapids (6 mi away, 7.3 mi from the station), Walker (7 mi away, 12.8 mi from the station), East Grand Rapids (8 mi away, 4.8 mi from the station), Kentwood (8 mi away, 2.5 mi from the station). Grandville is farther from the station than 4 of them.

The sun over Grandville in late July

At 42.90°N, the noon sun on 21 July stands 67.5° above the horizon over Grandville and the day runs 14 h 42 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.

17,094 people live in Grandville, the 60th largest of the 90 Michigan cities sized on this site. Coordinates used: 42.9005, -85.7521.

Grandville AC sizing questions

What size AC does a 2,000 sq ft house in Grandville, MI need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Grandville's climate.

Is 20 BTU per square foot right for Grandville?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Grand Rapids. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Grandville?

About $208 a year: 956 kWh at SEER2 14.3 and 21.73¢ per kWh, over 4 cooling months.