What size AC for Garfield Heights, OH? 2 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Garfield Heights needs
2 tons central AC or heat pump, about 25,700 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Cleveland Burke Lakefront Airport (8.1 mi away). Jul is the hottest month, averaging a high of 80.7°F and a low of 67.9°F, with about 9 days a year at 90°F or more. That gives a design temperature of 85°F against 75°F inside.
What it costs to run
About 1,285 kWh a year at SEER2 14.3, or roughly $242 at Ohio's average residential rate of 18.81¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Garfield Heights
Of the 25,700 BTU/hr, 7,200 comes through walls, roof and windows on a 85°F afternoon (28%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 3,300 is moisture the coil has to wring out of Garfield Heights's summer air (13%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 22,320 BTU/hr before the moisture allowance.
Other house sizes in Garfield Heights
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 14,100 | 1.5 tons | 2 tons |
| 1,500 sq ft | 19,900 | 1.5 tons | 2.5 tons |
| 2,500 sq ft | 31,500 | 3 tons | 5 tons |
| 3,000 sq ft | 37,300 | 3.5 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.
Month by month in Garfield Heights
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 35.3°F | 0 | 0 |
| Feb | 37.3°F | 0 | 0 |
| Mar | 44.9°F | 1 | 2 |
| Apr | 57.1°F | 8 | 10 |
| May | 67.9°F | 56 | 78 |
| Jun | 76.7°F | 178 | 248 |
| Jul | 80.7°F | 289 | 402 |
| Aug | 79.7°F | 261 | 363 |
| Sep | 73.5°F | 112 | 156 |
| Oct | 62.5°F | 18 | 26 |
| Nov | 50.5°F | 1 | 1 |
| Dec | 40.1°F | 0 | 0 |
Jul alone uses 31% of the year's cooling energy. The unit runs the equivalent of 716 hours a year at full output.
Garfield Heights against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Maple Heights, OH | 2 mi | 85°F | 2 tons |
| Bedford, OH | 4 mi | 85°F | 2 tons |
| Warrensville Heights, OH | 5 mi | 85°F | 2 tons |
| Seven Hills, OH | 5 mi | 88°F | 2.5 tons |
| Shaker Heights, OH | 5 mi | 85°F | 2 tons |
| Bedford Heights, OH | 5 mi | 85°F | 2 tons |
Of 176 Ohio cities here, Garfield Heights has the 141st highest cooling load. The range runs from Conneaut at 24,100 BTU/hr to Hamilton at 31,500.
Where Garfield Heights's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Cleveland Burke Lakefront Airport, 8.1 miles from the center of Garfield Heights at 582 ft above sea level. That is close enough that the station's summers are Garfield Heights's summers.
22 other cities use the same station and get the same climate inputs. The closest to Garfield Heights: Maple Heights (2 mi away, 9.8 mi from the station), Bedford (4 mi away, 11.6 mi from the station), Warrensville Heights (5 mi away, 9.8 mi from the station), Shaker Heights (5 mi away, 7.1 mi from the station), Bedford Heights (5 mi away, 12 mi from the station). Garfield Heights is farther from the station than 6 of them.
The sun over Garfield Heights in late July
At 41.42°N, the noon sun on 21 July stands 69.0° above the horizon over Garfield Heights and the day runs 14 h 33 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Long days mean the house keeps gaining heat into the evening, well after the outdoor peak.
29,014 people live in Garfield Heights, the 51st largest of the 176 Ohio cities sized on this site. Coordinates used: 41.4186, -81.6051.
Garfield Heights AC sizing questions
What size AC does a 2,000 sq ft house in Garfield Heights, OH need?
About 2 tons, for a cooling load of 25,700 BTU/hr on a 85°F design day. That is one ton per 935 square feet in Garfield Heights's climate.
Is 20 BTU per square foot right for Garfield Heights?
The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Cleveland Burke Lakefront Airport. For a single room here, plan on 12.8 BTU/hr per square foot.
What does central AC cost to run in Garfield Heights?
About $242 a year: 1,285 kWh at SEER2 14.3 and 18.81¢ per kWh, over 5 cooling months.