ACSizeCheck

What size AC for Franklin Park, PA? 2 tons for 2,000 sq ft

What size AC a 2,000 sq ft house in Franklin Park needs

2 tons central AC or heat pump, about 25,700 BTU/hr of load

The 20 BTU per square foot chart would put in 3.5 tons, about 64% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.

If a contractor quotes you more than 2 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 935 square feet in this climate. For a single room, size by the room: 12.8 BTU/hr per square foot.

The climate it is sized for

Climate from NOAA's 1991 to 2020 normals at Pittsburgh Asos (9.6 mi away). Jul is the hottest month, averaging a high of 82.9°F and a low of 63.4°F, with about 10 days a year at 90°F or more. That gives a design temperature of 87°F against 75°F inside.

What it costs to run

About 1,040 kWh a year at SEER2 14.3, or roughly $220 at Pennsylvania's average residential rate of 21.13¢ per kWh. Cooling runs 5 months of the year here.

What drives the load in Franklin Park

Of the 25,700 BTU/hr, 8,640 comes through walls, roof and windows on a 87°F afternoon (34%), 13,000 is sun on the house (51%), 2,120 is four people and their appliances, and 1,900 is moisture the coil has to wring out of Franklin Park's summer air (7%).

Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 23,760 BTU/hr before the moisture allowance.

Other house sizes in Franklin Park

HouseLoad, BTU/hrSize20 BTU/ft² chart
1,000 sq ft14,0001.5 tons2 tons
1,500 sq ft19,8001.5 tons2.5 tons
2,500 sq ft31,5003 tons5 tons
3,000 sq ft37,3003.5 tons5 tons

Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 1,900 BTU/hr; a 350 sq ft living room needs about 4,500 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 7,700 BTU/hr.

Month by month in Franklin Park

MonthAvg highCooling degree daysAC kWh
Jan36.3°F00
Feb39.6°F00
Mar49.1°F11
Apr62.4°F912
May71.9°F5673
Jun79.4°F161209
Jul82.9°F256334
Aug81.7°F219286
Sep75.1°F85111
Oct63.1°F1114
Nov50.9°F00
Dec40.6°F00

Jul alone uses 32% of the year's cooling energy. The unit runs the equivalent of 580 hours a year at full output.

Franklin Park against nearby cities

CityDistanceDesign daySize for 2,000 sq ft
Pittsburgh, PA12 mi87°F2.5 tons
Wilkinsburg, PA16 mi87°F2.5 tons
Baldwin, PA17 mi87°F2.5 tons
Whitehall, PA17 mi87°F2.5 tons
Munhall, PA17 mi87°F2.5 tons
New Kensington, PA18 mi87°F2.5 tons

Of 68 Pennsylvania cities here, Franklin Park has the 59th highest cooling load. The range runs from St. Marys at 21,700 BTU/hr to Philadelphia at 34,300.

Where Franklin Park's weather numbers come from

The nearest NOAA station with full 1991 to 2020 normals is Pittsburgh Asos, 9.6 miles from the center of Franklin Park at 1,119 ft above sea level. That is close enough that the station's summers are Franklin Park's summers.

No other city in this set uses Pittsburgh Asos, so this sizing is Franklin Park's alone.

The sun over Franklin Park in late July

At 40.59°N, the noon sun on 21 July stands 69.8° above the horizon over Franklin Park and the day runs 14 h 29 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.

15,079 people live in Franklin Park, the 37th largest of the 68 Pennsylvania cities sized on this site. Coordinates used: 40.5921, -80.0987.

Franklin Park AC sizing questions

What size AC does a 2,000 sq ft house in Franklin Park, PA need?

About 2 tons, for a cooling load of 25,700 BTU/hr on a 87°F design day. That is one ton per 935 square feet in Franklin Park's climate.

Is 20 BTU per square foot right for Franklin Park?

The chart gives 3.5 tons for 2,000 sq ft, against 2 tons sized from NOAA's 1991 to 2020 normals at Pittsburgh Asos. For a single room here, plan on 12.8 BTU/hr per square foot.

What does central AC cost to run in Franklin Park?

About $220 a year: 1,040 kWh at SEER2 14.3 and 21.13¢ per kWh, over 5 cooling months.