What size AC for Flowery Branch, GA? 3 tons for 2,000 sq ft
What size AC a 2,000 sq ft house in Flowery Branch needs
3 tons central AC or heat pump, about 34,300 BTU/hr of load
The 20 BTU per square foot chart would put in 3.5 tons, about 23% more than this climate needs. An oversized unit cools the air fast, shuts off before it pulls moisture out, and leaves the house cold and clammy.
If a contractor quotes you more than 3 tons for an average 2,000 sq ft house here, ask to see the Manual J load calculation behind it before you sign. That works out to one ton per 701 square feet in this climate. For a single room, size by the room: 17.1 BTU/hr per square foot.
The climate it is sized for
Climate from NOAA's 1991 to 2020 normals at Gainesville Lee Gilmer Mem Airport (8.6 mi away). Jul is the hottest month, averaging a high of 88.1°F and a low of 69.5°F, with about 35 days a year at 90°F or more. That gives a design temperature of 93°F against 75°F inside.
What it costs to run
About 2,406 kWh a year at SEER2 14.3, or roughly $372 at Georgia's average residential rate of 15.48¢ per kWh. Cooling runs 5 months of the year here.
What drives the load in Flowery Branch
Of the 34,300 BTU/hr, 12,960 comes through walls, roof and windows on a 93°F afternoon (38%), 13,000 is sun on the house (38%), 2,120 is four people and their appliances, and 6,200 is moisture the coil has to wring out of Flowery Branch's summer air (18%).
Sun is the biggest share here, more than heat through the walls, so shading west windows and a light roof cut the size you need more than extra insulation would. Sensible heat totals 28,080 BTU/hr before the moisture allowance.
Other house sizes in Flowery Branch
| House | Load, BTU/hr | Size | 20 BTU/ft² chart |
|---|---|---|---|
| 1,000 sq ft | 18,400 | 1.5 tons | 2 tons |
| 1,500 sq ft | 26,300 | 2.5 tons | 2.5 tons |
| 2,500 sq ft | 42,200 | 4 tons | 5 tons |
| 3,000 sq ft | 50,100 | 4 tons | 5 tons |
Single rooms with a window or mini-split unit: a 150 sq ft bedroom needs about 2,600 BTU/hr; a 350 sq ft living room needs about 6,000 BTU/hr; a 600 sq ft open plan kitchen and family room needs about 10,300 BTU/hr.
Month by month in Flowery Branch
| Month | Avg high | Cooling degree days | AC kWh |
|---|---|---|---|
| Jan | 51.2°F | 0 | 0 |
| Feb | 55°F | 0 | 1 |
| Mar | 63.2°F | 7 | 10 |
| Apr | 71.8°F | 39 | 57 |
| May | 78.9°F | 152 | 224 |
| Jun | 85.1°F | 323 | 476 |
| Jul | 88.1°F | 428 | 631 |
| Aug | 86.8°F | 400 | 590 |
| Sep | 81.4°F | 232 | 343 |
| Oct | 71.9°F | 47 | 69 |
| Nov | 61.5°F | 3 | 5 |
| Dec | 53.4°F | 1 | 1 |
Jul alone uses 26% of the year's cooling energy. The unit runs the equivalent of 1,004 hours a year at full output.
Flowery Branch against nearby cities
| City | Distance | Design day | Size for 2,000 sq ft |
|---|---|---|---|
| Buford, GA | 5 mi | 93°F | 3 tons |
| Braselton, GA | 7 mi | 93°F | 3 tons |
| Sugar Hill, GA | 9 mi | 93°F | 3 tons |
| Gainesville, GA | 10 mi | 93°F | 3 tons |
| Suwanee, GA | 12 mi | 95°F | 3 tons |
| Auburn, GA | 12 mi | 93°F | 3 tons |
Of 101 Georgia cities here, Flowery Branch has the 98th highest cooling load. The range runs from Cumming at 33,100 BTU/hr to Albany at 44,000.
Where Flowery Branch's weather numbers come from
The nearest NOAA station with full 1991 to 2020 normals is Gainesville Lee Gilmer Mem Airport, 8.6 miles from the center of Flowery Branch at 1,268 ft above sea level. That is close enough that the station's summers are Flowery Branch's summers.
6 other cities use the same station and get the same climate inputs. The closest to Flowery Branch: Buford (5 mi away, 13.9 mi from the station), Braselton (7 mi away, 11.4 mi from the station), Sugar Hill (9 mi away, 17.3 mi from the station), Gainesville (10 mi away, 1.2 mi from the station), Auburn (12 mi away, 17.8 mi from the station). Flowery Branch is farther from the station than 1 of them.
The sun over Flowery Branch in late July
At 34.17°N, the noon sun on 21 July stands 76.2° above the horizon over Flowery Branch and the day runs 13 h 57 min from sunrise to sunset. A lower noon sun puts more of the day's heat on east and west walls than on the roof, which is why shading west glass pays off here. Shorter days give the house a longer night to shed the day's heat.
12,292 people live in Flowery Branch, the 90th largest of the 101 Georgia cities sized on this site. Coordinates used: 34.1713, -83.9187.
Flowery Branch AC sizing questions
What size AC does a 2,000 sq ft house in Flowery Branch, GA need?
About 3 tons, for a cooling load of 34,300 BTU/hr on a 93°F design day. That is one ton per 701 square feet in Flowery Branch's climate.
Is 20 BTU per square foot right for Flowery Branch?
The chart gives 3.5 tons for 2,000 sq ft, against 3 tons sized from NOAA's 1991 to 2020 normals at Gainesville Lee Gilmer Mem Airport. For a single room here, plan on 17.1 BTU/hr per square foot.
What does central AC cost to run in Flowery Branch?
About $372 a year: 2,406 kWh at SEER2 14.3 and 15.48¢ per kWh, over 5 cooling months.